Ceiling diffusers direct the air from air conditioning systems into the room. The resulting airflow induces high levels of room air, thereby rapidly reducing the airflow velocity and the temperature difference between supply air and room air. Ceiling diffusers allow for large volume flow rates. The result is a mixed flow ventilation in comfort zones, with good overall room ventilation, creating only very little turbulence in the occupied zone.
Type DLK-AK ceiling diffusers have fixed blades. Horizontal air discharge is one-way to four-way. The supply air to room air temperature difference may range from –10 to +10 K.
Functional description
Ceiling diffusers direct the air from air conditioning systems into the room. The resulting airflow induces high levels of room air, thereby rapidly reducing the airflow velocity and the temperature difference between supply air and room air. Ceiling diffusers allow for large volume flow rates. The result is a mixed flow ventilation in comfort zones, with good overall room ventilation, creating only very little turbulence in the occupied zone.
Type DLK-AK ceiling diffusers have fixed blades. Horizontal air discharge is one-way to four-way. The supply air to room air temperature difference may range from –10 to +10 K.
Nominal sizes | 300, 400, 500, 600, 625 mm |
Minimum volume flow rate | 40 – 150 l/s or 144 – 540 m³/h |
Maximum volume flow rate, with LWA ≅ 50 dB(A) | 545 – 565 l/s or 1962 – 2034 m³/h |
Supply air to room air temperature difference | –10 to +10 K |
Quick sizing tables provide a good overview of the volume flow rates and corresponding sound power levels and differential pressures.
The maximum volume flow rates apply to a sound power level of approx. 50 dB (A).
Exact values for all parameters can be determined with our Easy Product Finder design programme.
Quick sizing tables provide a good overview of the volume flow rates and corresponding sound power levels and differential pressures.
The maximum volume flow rates apply to a sound power level of approx. 50 dB (A).
Exact values for all parameters can be determined with our Easy Product Finder design programme.
DLQ-AK-1, DLQ-AK-2, DLQ-AK-3, DLQ-AK-4 (supply air), sound power level and total differential pressure
300 | 40 | 144 | 10 | 16 | 12 | 19 | 18 | 23 |
300 | 65 | 234 | 26 | 31 | 32 | 34 | 47 | 38 |
300 | 95 | 342 | 56 | 42 | 67 | 45 | 101 | 49 |
300 | 120 | 432 | 90 | 50 | 107 | 53 | 161 | 57 |
400 | 50 | 180 | 4 | <15 | 6 | <15 | 10 | 13 |
400 | 105 | 378 | 19 | 28 | 25 | 32 | 42 | 35 |
400 | 160 | 576 | 45 | 41 | 58 | 45 | 99 | 48 |
400 | 215 | 774 | 81 | 50 | 105 | 54 | 178 | 57 |
500 | 100 | 360 | 5 | 16 | 7 | 19 | 14 | 23 |
500 | 180 | 648 | 16 | 32 | 22 | 35 | 46 | 39 |
500 | 260 | 936 | 33 | 43 | 47 | 46 | 97 | 50 |
500 | 340 | 1224 | 57 | 50 | 80 | 53 | 166 | 57 |
600 | 150 | 540 | 4 | 14 | 7 | 19 | 14 | 23 |
600 | 265 | 954 | 14 | 31 | 21 | 36 | 44 | 40 |
600 | 385 | 1386 | 29 | 42 | 44 | 47 | 94 | 51 |
600 | 505 | 1818 | 50 | 50 | 76 | 55 | 161 | 59 |
625 | 150 | 540 | 4 | 11 | 7 | 16 | 15 | 21 |
625 | 265 | 954 | 14 | 28 | 21 | 33 | 46 | 38 |
625 | 385 | 1386 | 29 | 39 | 44 | 44 | 97 | 49 |
625 | 545 | 1962 | 59 | 50 | 88 | 55 | 194 | 60 |
DLQ-AK-2E (supply air), sound power level and total differential pressure
300 | 40 | 144 | 9 | 16 | 11 | 18 | 17 | 22 |
300 | 65 | 234 | 24 | 31 | 28 | 33 | 45 | 37 |
300 | 95 | 342 | 50 | 42 | 61 | 44 | 96 | 48 |
300 | 120 | 432 | 80 | 50 | 97 | 52 | 153 | 56 |
400 | 50 | 180 | 4 | <15 | 6 | 9 | 10 | 13 |
400 | 105 | 378 | 19 | 28 | 25 | 31 | 45 | 35 |
400 | 160 | 576 | 45 | 41 | 59 | 44 | 104 | 48 |
400 | 215 | 774 | 82 | 50 | 106 | 53 | 188 | 57 |
500 | 100 | 360 | 5 | 12 | 7 | 16 | 15 | 20 |
500 | 180 | 648 | 16 | 30 | 23 | 34 | 47 | 38 |
500 | 260 | 936 | 34 | 41 | 47 | 45 | 98 | 49 |
500 | 350 | 1260 | 61 | 50 | 86 | 54 | 178 | 58 |
600 | 150 | 540 | 4 | 11 | 7 | 15 | 13 | 20 |
600 | 265 | 954 | 13 | 29 | 21 | 33 | 41 | 38 |
600 | 385 | 1386 | 27 | 41 | 43 | 45 | 87 | 50 |
600 | 515 | 1854 | 48 | 50 | 78 | 54 | 155 | 59 |
625 | 150 | 540 | 4 | 8 | 7 | 13 | 14 | 17 |
625 | 265 | 954 | 13 | 26 | 21 | 31 | 42 | 35 |
625 | 385 | 1386 | 27 | 38 | 43 | 43 | 89 | 47 |
625 | 565 | 2034 | 58 | 50 | 93 | 55 | 193 | 59 |
Ceiling diffusers with square diffuser face. For supply air only, for comfort zones. Diffuser face with fixed air control blades for horizontal one-way to four-way supply air discharge. For installation into all types of suspended ceilings.
Ready-to-install component which consists of the diffuser face with fixed air control blades, front frame with perimeter seal, plenum box, side entry spigot and suspension holes.
Spigot suitable for ducts to EN 1506 or EN 13180.
Sound power level of the air-regenerated noise measured according to EN ISO 5135.
Special characteristics
Materials and surfaces
Technical data
Sizing data
Air-regenerated noise
Ceiling diffusers with square diffuser face. For supply air only, for comfort zones. Diffuser face with fixed air control blades for horizontal one-way to four-way supply air discharge. For installation into all types of suspended ceilings.
Ready-to-install component which consists of the diffuser face with fixed air control blades, front frame with perimeter seal, plenum box, side entry spigot and suspension holes.
Spigot suitable for ducts to EN 1506 or EN 13180.
Sound power level of the air-regenerated noise measured according to EN ISO 5135.
Special characteristics
Materials and surfaces
Technical data
Sizing data
Air-regenerated noise
Order example: DLQ-AK-3-M/600/P1-RAL 9006/A
No. of sides for air discharge | 3 |
Connection | Plenum box, horizontal connection |
Damper blade for volume flow rate balancing | With |
Nominal size | 600 |
Exposed surface | RAL 9006, white aluminium, gloss level 30% |
Spigot side | A |
Installation and commissioning
These are only schematic diagrams to illustrate installation details.
Installation and commissioning
These are only schematic diagrams to illustrate installation details.
Principal dimensions
ØD [mm]
Outer diameter of the spigot
ØD₁ [mm]
Outer diameter of a circular diffuser face
ØD₂ [mm]
Diameter of a circular diffuser face style
ØD₃ [mm]
Diameter of a circular plenum box
□Q₁ [mm]
Outer diameter of a square diffuser face
□Q₂ [mm]
Dimensions of a square diffuser face style
□Q₃ [mm]
Dimensions of a square plenum box
H₁ [mm]
Distance (height) from the lower edge of the suspended ceiling to the lower edge of the diffuser face
H₂ [mm]
Height of a ceiling diffuser, from the lower edge of the suspended ceiling to the upper edge of the spigot
H₃ [mm]
Height of a ceiling diffuser with plenum box, from the lower edge of the suspended ceiling to the upper edge of the plenum box or of the spigot
A [mm]
Position of the spigot, defined by the distance of the spigot centre line to the lower edge of the suspended ceiling
C [mm]
Length of the spigot
m [kg]
Weight
Nomenclature
LWA [dB(A)]
A-weighted sound power level of air-regenerated noise
V [m³/h] and [l/s]
Volume flow rate
Δtz [K]
Supply air to room air temperature difference, i.e. supply air temperature minus room temperature
Δpt [Pa]
Total differential pressure
Aeff [m²]
Effective air discharge area
All sound power levels are based on 1 pW.
Principal dimensions
ØD [mm]
Outer diameter of the spigot
ØD₁ [mm]
Outer diameter of a circular diffuser face
ØD₂ [mm]
Diameter of a circular diffuser face style
ØD₃ [mm]
Diameter of a circular plenum box
□Q₁ [mm]
Outer diameter of a square diffuser face
□Q₂ [mm]
Dimensions of a square diffuser face style
□Q₃ [mm]
Dimensions of a square plenum box
H₁ [mm]
Distance (height) from the lower edge of the suspended ceiling to the lower edge of the diffuser face
H₂ [mm]
Height of a ceiling diffuser, from the lower edge of the suspended ceiling to the upper edge of the spigot
H₃ [mm]
Height of a ceiling diffuser with plenum box, from the lower edge of the suspended ceiling to the upper edge of the plenum box or of the spigot
A [mm]
Position of the spigot, defined by the distance of the spigot centre line to the lower edge of the suspended ceiling
C [mm]
Length of the spigot
m [kg]
Weight
Nomenclature
LWA [dB(A)]
A-weighted sound power level of air-regenerated noise
V [m³/h] and [l/s]
Volume flow rate
Δtz [K]
Supply air to room air temperature difference, i.e. supply air temperature minus room temperature
Δpt [Pa]
Total differential pressure
Aeff [m²]
Effective air discharge area
All sound power levels are based on 1 pW.
Share page
Recommend this page
Recommend this page by sending a link by mail.
Share page
Thank you for your recommendation!
Your recommendation has been sent and should arrive shortly.
Contact
We are here for you
Please specify your message and type of request
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265
Contact
Thank you for your message!
Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265
Contact
We are here for you
Please specify your message and type of request
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265
Contact
Thank you for your message!
Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265