FK2-EU_img_90psd.png

FK2-EU with fusible link for 72 °C or 95 °C

CE-Kennzeicheneps.eps.link

CE compliant according to European regulations

ASi_LonMarkai.ai.link

With TROXNETCOM as an option

ATEX-Zertifizierung_01ai.png

ATEX certification

VDI6022_gs_01ai.ai.link

Tested to VDI 6022

FK2-EU_img_90psd.png
CE-Kennzeicheneps.eps.link
ASi_LonMarkai.ai.link
ATEX-Zertifizierung_01ai.png
VDI6022_gs_01ai.ai.link

FK2-EU  

For diverse applications

  • Nominal sizes 200 × 100 – 1500 × 800 mm, can be ordered in increments of 1 mm

  • Low differential pressure and sound power level

  • Explosion-proof construction (ATEX) as an option

  • Optionally available as an upstream shutter of an air transfer unit

  • Can also be used as an air transfer damper

  • Optional stainless steel casing or powder-coated casing for increased corrosion protection

  • Optionally available with thermal insulation to prevent condensation

  • Integration into the central BMS with TROXNETCOM

  • Universal installation options


Optional equipment and accessories

  • Electric actuator 24 V/230 V

  • Release temperature 72/95 °C  
     

 

Useful additions

  • Duct smoke detectors

Updating order code
Save configuration
Calculate price
Updating technical data
  • Media
Specification text:
Updating specification text
Show complete text Hide complete text
Initialize order code

General information

Application

  • Fire dampers with CE marking and declaration of performance, for the isolation of duct penetrations between two fire compartments in the event of a fire

  • To prevent the propagation of fire and smoke through ductwork to adjacent designated fire compartments



Special features

  • Declaration of performance in accordance with European Construction Products Regulation

  • Classification according to EN 13501-3, up to EI 240 (ve, ho, i ↔ o) S

  • Complies with the requirements of EN 15650

  • Tested for fire resistance properties in accordance with EN 1366-2 (300 Pa and 500 Pa negative pressure)

  • Certified mortar-based installation with reduced distances of 40 mm to supporting components or 60 mm between two fire dampers (flange to flange)

  • Perimeter gap may be up to 225 mm for mortar-based installation

  • 2 inspection accesses with bayonet fixing for single-handed operation

  • Meets the hygiene requirements of VDI 6022-1, VDI 3803-1, DIN 1946-4, EN 13779, of Ö-Norm H 6020 and H 6021, and of SWKI

  • Corrosion protection according to EN 15650 in connection with EN 60068-2-52

  • Closed blade air leakage to EN 1751, class 2

  • Casing air leakage to EN 1751, class C (B + H ≤700, class B)

  • Low differential pressure and sound power level

  • Any airflow direction

  • Integration into the central building management system with the international standard fire damper system in accordance with IEC 62026-2 with AS interface is possible


Classification

Performance class up to EN 13501-3, up to EI 240 (ve, ho, i ↔ o) S



Nominal sizes

  • B × H: 200 × 100 – 1500 × 800 mm (Intermediate sizes can be ordered in 1 mm increments)

  • L: 305 mm or 500 mm


Variants

  • With fusible link

  • With fusible link for use in potentially explosive atmospheres

  • With spring return actuator

  • With spring return actuator for use in potentially explosive atmospheres

  • With spring return actuator and duct smoke detector

  • With cover grille on both sides as an upstream shutter of an air transfer unit

  • With spring return actuator, duct smoke detector and cover grilles at both ends for use as an air transfer damper according to general building inspectorate licence Z-6.50-2540




The following applies to Germany:

If fire dampers with a purely mechanical shut-off element are to be used as an upstream shutter of an air transfer unit, the local building regulations must be observed. Usually the use of such upstream shutters of air transfer units is restricted to pressure differential systems.



Parts and characteristics

  • Release temperature 72 °C or 95 °C (for use in warm air ventilation systems)

  • Single-handed operation

  • Explosion-proof constructions for zones 1, 2, 21, 22


Attachments

  • Limit switch for damper blade position indication

  • Spring return actuator for 24 V AC/DC or 230 V AC supply voltage

  • Limit switch for damper blade position indication for use in potentially explosive atmospheres

  • Spring return actuator for 24 – 230 V supply voltage, for use in potentially explosive atmospheres

  • Network module for the integration with AS-i or LON networks

  • Spring return actuator and wired duct smoke detector with 230 VAC, 50/60 Hz or 24 VDC supply voltage

  • All attachments can be retrofitted


Accessories

  • Installation kit ES for dry mortarless installation in lightweight partition walls, compartment walls, safety partition walls and radiation protection walls with metal support structures or steel support structures, and cladding on both sides

  • Installation kit ES for dry mortarless installation in timber stud walls/half-timbered construction as well as solid wood and cross laminated timber walls

  • Installation kit ES for dry mortarless installation in shaft walls with metal support structure or steel support structure as well as shaft walls without metal support structure

  • Installation kit ES for dry mortarless installation in wooden beam ceilings and solid wood ceilings

  • Installation kit E3 for dry mortarless installation in solid walls in an existing installation subframe E1/E2 of the FK-K90 or FK-EU

  • Installation kit EW for dry mortarless installation in solid walls with installation subframe

  • Installation kit GM for installation into solid non-load-bearing walls with flexible ceiling joint

  • Installation kit WA for dry mortarless installation on the face of solid walls and ceiling slabs

  • Installation kit WE for dry mortarless installation remote from solid walls, remote from solid ceiling slabs, and remote from lightweight partition walls with metal support structure and cladding on both sides

  • Installation kit GL for dry mortarless installation in lightweight partition walls with metal support, cladding on both sides and flexible ceiling joint

  • Cover grille

  • Flexible connectors

  • Circular spigots

  • Profile connecting frame


Useful additions

  • Duct smoke detector RM-O-3-D

  • Duct smoke detector with airflow monitor RM-O-VS-D


Construction features

  • Rectangular or square construction, rigid casing, both flanges with fixing holes

  • Suitable for the connection of ducts, cover grilles, spigots, flexible connectors or profile connecting frames

  • The release mechanism is accessible and can be tested from the outside

  • 2 inspection access panels, Ø110 mm, which can be opened without any tools

  • Remote control with spring return actuator


Materials and surfaces

TROX casing:

  • Galvanised sheet steel

  • Galvanised sheet steel, powder-coated RAL 7001

  • Stainless steel 1.4301



Damper blade:

  • Special insulation material

  • Special insulation material with impregnation




ODA construction:

  • Damper casing made of galvanised sheet steel with powder coating and thermal insulation, damper blade made of special insulating material with impregnation (only in conjunction with spring return actuator)




Other components:

  • Damper blade shafts and drive linkage made of galvanised steel, in constructions -1 and -2 made of stainless steel

  • Plastic bearings

  • EPDM and TPE seals


The construction variants with stainless steel or powder-coated casing meet even more critical requirements for corrosion protection. Detailed listing on request.


Standards and guidelines

  • Construction Products Regulation

  • EN 15650 Ventilation for buildings – Fire dampers

  • EN 1366-2 Fire resistance tests for service installations – Fire dampers

  • EN 13501-3 Fire classification of construction products and building elements

  • EN 1751 Ventilation for buildings – Air terminal devices

  • 2006/42/EC – Machinery Directive


Supply package

If attachments and accessories are supplied from the factory with the fire dampers, they are already taken into account in the order code. Depending on the installation situations, supplementary materials for assembly and fixing may be needed to ensure proper installation, e.g. mortar, screws, mineral wool, etc. Such materials are not included in the supply package, unless they are expressly described as included in the supply package. The selection of additional attachments or accessories as well as the identification and provision of materials for assembly and fixing is the responsibility of those involved in the building project and must be done taking into account the required classification.




Maintenance

  • The functional reliability of the fire damper must be tested at least every six months; this has to be arranged by the owner of the ventilation system; functional tests must be carried out in compliance with the basic maintenance principles stated in EN 13306 and DIN 31051. If 2 consecutive tests, one 6 months after the other, are successful, the next test on the fire damper can be conducted one year later.

  • A functional test involves closing the damper blade and opening it again; with a spring return actuator this can be done via remote control

  • Fire dampers must be included in the regular cleaning schedule for the ventilation system

  • For details on functional tests, maintenance and inspection, refer to the installation and operating manual


Technical data

  • Nominal sizes: 200 × 100 to 1500 × 800 mm

  • Casing lengths: 305 and 500 mm

  • Volume flow rate range: up to 14400 l/s / up to 51840 m³/h

  • Differential pressure: up to 2000 Pa

  • Temperature range: -20 – 50 °C

  • Upstream velocity*: Standard construction ≤ 8 m/s, construction with spring return actuator ≤ 12 m/s, construction with explosion-proof actuator ExMax/RedMax-15-BF TR ≤ 10 m/s

* Data applies to uniform upstream and downstream conditions for the fire damper


Incorrect use:

  • Without specially approved attachments in areas with potentially explosive atmospheres

  • As a smoke control damper

  • Outdoors without sufficient protection against the effects of weather

  • In atmospheres where chemical reactions, whether planned or unplanned, may cause damage to the fire damper or lead to corrosion


The following applies to installation in Germany:

  • Do not use it in extract air systems in commercial kitchens

  • Use as air transfer damper only according to general type approval Z-6.50-2540

  • Do not use in combined penetration seal

  • Approvals under building regulations may be required for the use of upstream shutters of air transfer units. This must be checked and applied for by others

  • Flame-resistant building materials that form no dripping droplets (elastomer foams) have to be at least of fire rating class C - s2, d0 according to the German M‑VV TB (since 2019/01) guideline. The applicable national building regulations must be adhered to.

Technical information

Function, Technical Data, Quick sizing, Specification Text, Order Code

  • Function
  • TECHNICAL DATA
  • QUICK SIZING
  • SPECIFICATION TEXT
  • ORDER CODE

In the event of a fire, fire dampers shut automatically to prevent the propagation of fire and smoke through ductwork to adjacent designated fire compartments. In the event of a fire, the damper is triggered at 72 °C or at 95 °C (use in warm air ventilation systems) by a fusible link. The release mechanism is accessible and can be tested from the outside. One or two limit switches (optional attachment) can be used to indicate the damper blade position.

 


Nominal sizes200 × 100 – 1500 × 800 mm ⁴
Casing lengths305 and 500 mm
Volume flow rate rangeUp to 14400 l/s or 51840 m³/h
Differential pressure rangeUp to 2000 Pa

Temperature range 1, 3

-20 to 50 °C
Release temperature72 °C or 95 °C (for warm air ventilation systems)
Upstream velocity ²

Standard construction ≤ 8 m/s, construction with spring return actuator ≤ 12 m/s, construction with explosion-proof actuator ExMax/RedMax-15-BF TR ≤ 10 m/s

¹ Temperatures may differ for units with attachments. Details for other applications are available on request.
² Data applies to uniform upstream and downstream conditions for the fire damper.
³ Condensation and the intake of humid outdoor air have to be avoided as otherwise operation will be impaired or not possible.
⁴ Damper blade with lip seal for sizes 1 and 2, damper blade with travel stop seal for size 3.


 


For sizes see the functional description.

Free area and resistance coefficient, width 200 – 800 mm

H

(1)

B

200

250

300

350

400

450

500

550

600

650

700

750

800

100A [m²]0.0130.0160.020.0230.0270.030.0340.0370.0410.0440.0480.0510.055
100ζ1.050.960.880.830.780.750.710.690.660.640.620.610.59
125A [m²]0.01750.02220.0270.03170.03650.04120.0460.05070.05550.06020.0650.06970.0745
125ζ0.930.850.780.730.690.660.630.610.590.570.550.540.52
150A [m²]0.02210.02810.03410.04010.04610.05210.05810.06410.07010.07610.08210.08810.0941
150ζ0.850.770.710.670.630.60.580.550.540.520.50.490.48
160A [m²]0.0240.030.0370.0430.050.0560.0630.0690.0760.0820.0890.0950.102
160ζ0.660.60.550.520.490.470.450.430.410.40.390.380.37
200A [m²]0.0310.040.0480.0570.0650.0740.0820.0910.0990.1080.1160.1250.133
200ζ0.740.670.620.580.550.520.50.480.470.450.440.430.41
250A [m²]0.03970.05070.06170.07270.08370.09470.10570.11670.12770.13870.14970.16070.1717
250ζ0.670.610.560.530.50.470.450.440.420.410.40.380.37
300A [m²]0.04890.06240.07590.08940.10290.11640.12990.14340.15690.17040.18390.19740.2109
300ζ0.620.560.520.490.460.440.420.40.390.380.360.350.34
350A [m²]0.05810.07410.09010.10610.12210.13810.15410.17010.18610.20210.21810.23410.2501
350ζ0.580.520.480.450.430.410.390.380.360.350.340.330.32
400A [m²]0.06730.08580.10430.12280.14130.15980.17830.19680.21530.23380.25230.27080.2893
400ζ0.540.490.460.430.40.390.370.350.340.330.320.310.3
450A [m²]0.07650.09750.11850.13950.16050.18150.20250.22350.24450.23550.25480.27410.2934
450ζ0.570.510.470.430.410.390.370.350.340.330.320.310.3
500A [m²]0.08570.10920.13270.15620.17970.20320.22670.25020.27370.2660.28780.30960.3314
500ζ0.540.480.440.410.390.370.350.340.330.310.30.30.29
550A [m²]0.12640.15070.1750.19930.22360.24790.27220.29650.32080.34510.3694
550ζ0.420.40.370.350.340.320.310.30.290.280.28
600A [m²]0.13940.16620.1930.21980.24660.27340.30020.3270.35380.38060.4074
600ζ0.410.380.360.340.320.310.30.290.280.270.27
650A [m²]0.15240.18170.2110.24030.26960.29890.32820.35750.38680.41610.4454
650ζ0.390.370.350.330.310.30.290.280.270.260.26
700A [m²]0.16540.19720.2290.26080.29260.32440.35620.3880.41980.45160.4834
700ζ0.380.350.330.320.30.290.280.270.260.250.25
750A [m²]0.17840.21270.2470.28130.31560.34990.38420.41850.45280.48710.5214
750ζ0.370.340.320.310.290.280.270.260.250.250.24
800A [m²]0.19140.22820.2650.30180.33860.37540.41220.4490.48580.52260.5594
800ζ0.360.330.320.30.290.270.260.260.250.240.23

(1) Parameters


Free area and resistance coefficient, width 850 – 1500 mm

H

Parameter

B

900

1000

1100

1200

1300

1400

1500

200

A [m²]

0.117

0.1665

0.1442

0.1578

0.1714

0.185

0.1986

200

ζ

0.44

0.42

0.40

0.39

0.38

0.36

0.35

250

A [m²]

0.16

0.2157

0.1972

0.2158

0.2344

0.253

0.2716

250

ζ

0.39

0.37

0.35

0.34

0.33

0.32

0.31

300

A [m²]

0.203

0.2649

0.2502

0.2738

0.2974

0.321

0.3446

300

ζ

0.35

0.34

0.32

0.31

0.30

0.29

0.28

350

A [m²]

0.246

0.2746

0.3032

0.3318

0.3604

0.389

0.4176

350

ζ

0.32

0.31

0.30

0.29

0.28

0.27

0.26

400

A [m²]

0.289

0.3226

0.3562

0.3898

0.4234

0.457

0.4906

400

ζ

0.30

0.29

0.28

0.27

0.26

0.25

0.25

450

A [m²]

0.332

0.3706

0.4092

0.4478

0.4864

0.525

0.5636

450

ζ

0.29

0.28

0.26

0.26

0.25

0.24

0.23

500

A [m²]

0.375

0.4186

0.4622

0.5058

0.5494

0.593

0.6366

500

ζ

0.27

0.26

0.25

0.24

0.24

0.23

0.22

550

A [m²]

0.418

0.4666

0.5152

0.5638

0.6124

0.661

0.7096

550

ζ

0.26

0.25

0.24

0.23

0.23

0.22

0.21

600

A [m²]

0.461

0.5146

0.5682

0.6218

0.6754

0.729

0.7826

600

ζ

0.25

0.24

0.23

0.22

0.22

0.21

0.20

650

A [m²]

0.504

0.5626

0.6212

0.6798

0.7384

0.797

0.8556

650

ζ

0.24

0.23

0.22

0.22

0.21

0.20

0.20

700

A [m²]

0.547

0.6106

0.6742

0.7378

0.8014

0.865

0.9286

700

ζ

0.24

0.23

0.22

0.21

0.20

0.20

0.19

750

A [m²]

0.59

0.6586

0.7272

0.7958

0.8644

0.933

1.0016

750

ζ

0.23

0.22

0.21

0.20

0.20

0.19

0.19

800

A [m²]

0.633

0.7066

0.7802

0.8538

0.9274

1.01

1.0746

800

ζ

0.22

0.21

0.20

0.20

0.19

0.19

0.18

Quick sizing tables provide a good overview of the volume flow rates with different sound power levels as well as of differential pressures of up to 35 Pa. Approximate intermediate values can be interpolated. Precise intermediate values can be calculated with our Easy Product Finder design program. You can find this on our website at: 
www.trox.de/mytrox/auslegungsprogramm-easy-poduct-finder-182e16348fac3d33

Volume flow rate qv in [m³/h] for differential pressure Δpst 35 Pa
200 – 650 mm

H

LWA [dB(A)]

B

200

250

300

350

400

450

500

550

600

650

10035390484577668759849938102711161205
1253550762774586297810931208132214351548
150356197649071048118813261464160117371873
1603572889710631227139015501710186920272185
20035835102812161402158617691950213023092487
250351026126414961725195121742396261628353053
300351232151217862056232125842844310333603615
350351434175720712379268329843281357738704161
400351634199723512698303933773710404143694696
450351474185622252585293832863629396943054640
500351647207124802878326936524031440647785146
5503527333169359540154429483852435645
6003529833456391943744823526657046139
6503532323742424147305213568961606627
7003534794026456050845600610966137112
7503537254308487754355984652670627592
8003539704589519357846367694175088070


Volume flow rate qv in [m³/h] for differential pressure Δpst 35 Pa
700 – 1500 mm

H

LWA [dB(A)]

B

700

750

800

900

1000

1100

1200

1300

1400

1500

100

35

1293

1380

1468

125

35166017721883
15035200821422276
16035234124972653
200352664284130172633291531963476375440314308
250353270348637013422378541474506486452215576
300353869412243744172461150485482591563456774
350354451473950274895540659146419692274237922
400355020534356645597617767537327789784659031
4503549725302563062826929757282118847948010110
50035551258756237695576678374907797761047111164
550356044644068347616839291629926106871144412198
6003565706998742482699107993810763115841240113214
65035709175518008891498131070411589124691334414216
700357606809885859553105111146112405133431427615204
7503581188640915810186112031221113213142081519716181
8003586269178972710813118891295514013150641610917149


Volume flow rate qv in [m³/h] for differential pressure Δpst 35 Pa
200 – 650 mm

H

LWA [dB(A)]

B

200

250

300

350

400

450

500

550

600

650

100

45

525

690

841

975

1107

1239

1369

1499

1629

1758

125

45

710

870

1088

1258

1427

1595

1762

1928

2094

2258

150

45

880

1115

1323

1529

1733

1935

2136

2336

2534

2732

160451063130915521791202822622496272729583188
200451219149917752046231425802845310733683628
250451498184421832517284631733496381841374455
300451797220726072999338737704150452749025274
350452092256330223472391543544788521856466071
400452384291534313937443549275413589663756851
450452151270932473772428747945295579062826769
500452404302236194200476953295882642969717508
5504539874623524658586462705976508237
6004543535043571863827036768383228957
6504547155460618769027605830089889669
70045507658746653741881708913964810376
750455435628671167930873195221030311077
8004557926695757684409289101271095411774


Volume flow rate qv in [m³/h] for differential pressure Δpst 35 Pa
700 – 1500 mm

H

LWA [dB(A)]

B

700

750

800

900

1000

1100

1200

1300

1400

1500

10045188620142142
12545242225852748
15045292931263322
16045341636443871
200453887414544023842425446635071547758826285
250454771508654004993552360506575709776178136
300455645601463826088672873657999863092589884
350456494691573347142788886299366101001083011558
4004573247795826481669012985310690115221235113177
450457254773582149166101101104811980129081383114751
5004580428572910010147111861221713243142631527816289
5504588189397997111113122441336714483155931669717797
600459586102111083212065132871449915704169021809319280
6504510345110161168313006143171561716908181921947020741
7004511098118141252613938153361672218099194672082822183
7504511844126061336214861163451781619277207292217223609
8004512586133911419115777173461890120444219782350325020


Sizing example

Given data           Quick sizing
Volume flow rate: 3350 m³/h   FK2-EU/400×300×500
Maximum width: 300 mm
Sound power level: 45 dB(A)

Specification text

Fire damper that meets the requirements of the European product standard EN 15650, square or rectangular, with two large inspection accesses that can be opened without tools. Tested for fire resistance properties to EN 1366-2 (negative pressure of 300 Pa and 500 Pa), with CE marking. The fire damper manufacturer's declaration of performance (DoP) provides proof that a product is suitable for the respective installation conditions, e.g. in, on the face of and remote from walls or ceilings, with the stated essential characteristics such as size, supporting construction, construction and installation type, and that it has the corresponding class of performance to EN 13501-3. The ready-for-operation unit includes a release mechanism and a replaceable, fire-resistant damper blade, which, depending on the application, can be either horizontal or vertical. Classification (depending on application):

EI 30 (ve, ho i ↔ o) S to EI 240 (ve, ho i ↔ o) S


Suitable for:

Mortar-based installation

  • In solid walls, walls made from gypsum wall boards, lightweight partition walls, compartment walls, safety partition walls and walls to provide radiation protection
  • In solid walls with partial mortaring
  • With installation kit for flexible ceiling joints in solid walls
  • In shaft walls with metal support structures or steel support structures
  • In timber stud walls and timber frame walls, as well as solid wood and cross laminated timber walls
  • In and on solid walls and in combination with timber beam, solid wood and modular ceilings (System Cadolto)
  • In solid wood ceilings, wooden beam ceilings and historical wooden beam ceilings
  • Multiple occupancy up to 4.8 m² total fire damper surface area in solid walls and ceiling slabs, lightweight partition walls as well as timber stud walls and half-timbered constructions
  • Combined installation with FKRS-EU and FKR-EU in solid walls and ceiling slabs, lightweight partition walls, shaft walls as well as timber stud walls and half-timbered constructions up to 1.2 m² total fire damper surface area
  • In lightweight partition walls, compartment walls, safety partition walls and radiation protection walls with metal support structures or steel support structures
  • 4-fold arrangement up to 4.8 m² total fire damper surface area with common duct in solid walls, lightweight partition walls as well as timber stud walls and half-timbered constructions
  • Mortar-based installation in concrete base on solid ceiling slabs, also combined with FKRS-EU and FKR-EU as well as multiple occupancy up to 4.8 m² total fire damper surface area
  • In hollow-stone, hollow-section, ribbed and composite ceiling slabs



Dry mortarless installation

  • In lightweight partition walls, compartment walls, safety partition walls and radiation protection walls with metal support structures or steel support structures
  • In lightweight partition walls with metal support structure and cladding on both sides, and with flexible ceiling joint
  • In timber stud walls and timber frame walls, as well as solid wood and cross laminated timber walls
  • In solid walls with installation kit E3 in an existing installation subframe E1/E2 of the FK-K90 or FK-EU
  • In solid walls with installation kit EW and installation subframe
  • With gypsum board/gypsum plaster fire protection panels in lightweight partition walls with metal support
  • With mineral wool in lightweight partition wall with metal support, timber stud walls and half-timbered constructions as well as solid wood walls
  • In shaft walls with metal support structure or steel support structure, and in shaft walls without metal support structure
  • In solid wood and wooden beam ceilings
  • With an installation kit on the face of and remote from solid walls and ceiling slabs
  • Remote from lightweight partition walls (wall penetration)


Fire batt installation

  • In solid walls and ceiling slabs
  • In lightweight partition walls, compartment walls, safety partition walls and walls to provide radiation protection, with metal support structure or steel support structure
  • In timber stud walls, half-timbered constructions, solid wood walls and CLT walls
  • Multiple occupancy up to 2.4 m² total fire damper surface area in solid walls and ceiling slabs, lightweight partition walls as well as timber stud walls and half-timbered constructions






Size dimensions from (B × H) 200 mm × 100 mm – 1500 mm × 800 mm, intermediate sizes can be ordered in 1 mm increments.

Optimised low-leakage casing, up to leakage class C to EN 1751 with low differential pressure and low sound power level.

Fire damper casing made of galvanised sheet steel, optionally galvanised sheet steel with powder coating RAL 7001 or stainless steel 1.4301.
Damper blade made of special insulation material; coating as an option.

Corrosion protection according to EN 15650 in connection with EN 60068-2-52. Hygienic requirements are fulfilled in accordance with VDI 6022-1, VDI 3803-1, DIN 1946-4, DIN EN 13779 as well as the Önorm H 6020 and H 6021 and the SWKI. Casing length 305 mm or 500 mm with a 30 mm (L = 500 mm) flange for the connection to ducts made of non-combustible or combustible materials. Thermal release at 72 °C or 95 °C (warm air ventilation systems) with a fusible link or thermoelectrically with a spring return actuator, push button and indicator light (LED). Constructions with a brushless actuator for opening and closing the fire damper, also when the ventilation system is running and independent of the nominal size, are particularly suitable for functional checks and for shutting off sections of the duct system. Retrofit of spring return actuators without modification of the rod is possible from the outside.

Explosion-proof constructions for zones 1, 2, 21 and 22 available with limit switch or spring return actuator.



In the version with thermal insulation made of 32 mm synthetic cellular rubber, fire rating class: B-s2-d0, spring return actuator and perimeter mortar infill, suitable for reducing condensation in the case of outdoor air intake (ODA Outdoor air)


Special features

  • Declaration of performance in accordance with European Construction Products Regulation
  • Classification to EN 13501-3, to EI 240 (ve, ho, i ↔ o) S
  • Complies with the requirements of EN 15650
  • Tested for fire resistance properties in accordance with EN 1366-2 (300 Pa and 500 Pa negative pressure)
  • Certified mortar-based installation with reduced distances of 40 mm to supporting components or 60 mm between two fire dampers (flange to flange)
  • Perimeter gap may be up to 225 mm for mortar-based installation
  • 2 inspection accesses with bayonet fixing for single-handed operation
  • Meets the hygiene requirements of VDI 6022-1, VDI 3803-1, DIN 1946-4, EN 13779, of Ö-Norm H 6020 and H 6021, and of SWKI
  • Corrosion protection according to EN 15650 in connection with EN 60068-2-52
  • Closed blade air leakage to EN 1751, class 2
  • Casing air leakage to EN 1751, class C (B + H ≤700, class B)
  • Low differential pressure and sound power level
  • Any airflow direction
  • Integration into the central building management system with the international standard fire damper system in accordance with IEC 62026-2 with AS interface is possible


Technical data

  • Nominal sizes: 200 × 100 to 1500 × 800 mm
  • Casing lengths: 305 and 500 mm
  • Volume flow rate range: up to 14400 l/s / up to 51840 m³/h
  • Differential pressure: up to 2000 Pa
  • Temperature range: -20 – 50 °C
  • Upstream velocity*: Standard construction ≤ 8 m/s, construction with spring return actuator ≤ 12 m/s, construction with explosion-proof actuator ExMax/RedMax-15-BF TR ≤ 10 m/s

* Data applies to uniform upstream and downstream conditions for the fire damper


Materials and surfaces

TROX casing:

  • Galvanised sheet steel
  • Galvanised sheet steel, powder-coated RAL 7001
  • Stainless steel 1.4301


 



Damper blade:

  • Special insulation material
  • Special insulation material with impregnation




ODA construction:

  • Damper casing made of galvanised sheet steel with powder coating and thermal insulation, damper blade made of special insulating material with impregnation (only in conjunction with spring return actuator)




Other components:

  • Damper blade shafts and drive linkage made of galvanised steel, in constructions -1 and -2 made of stainless steel
  • Plastic bearings
  • EPDM and TPE seals

 


The construction variants with stainless steel or powder-coated casing meet even more critical requirements for corrosion protection. Detailed listing on request.


Equivalence criteria

  • The declaration of performance according to the Construction Products Regulation describes all CE-certified installation types including the performance class up to EI 240 S according to EN 13501-3 as well as the essential characteristics of at least the permissible size and supporting structure

  • Hygienic requirements are fulfilled in accordance with VDI 6022-1, VDI 3803-1, DIN 1946-4, DIN EN 13779 as well as the Önorm H 6020 and H 6021 and the SWKI.
  • CE-marked and thus tested for fire protection according to EU regulation 305/2011 and evaluated according to machinery directive 2006/42/EC
  • CE-certified mortar-based installation at a distance ≥ 60mm between 2 fire dampers (flange to flange)
  • Combined installation with FKRS-EU and FKR-EU in solid walls and ceiling slabs, lightweight partition walls, shaft walls as well as timber stud walls and half-timbered constructions up to 1.2 m² total fire damper surface area
  • 2 inspection access panels Ø110 mm, with bayonet fixing (can be opened without tools)
  • Pressure loss < 15 Pa at reference size 400 × 200 mm and 6 m/s face velocity
  • Sound power < 38 dB (A) at reference size 400 × 200 mm and 6 m/s face velocity
  • Multiple occupancy up to 4.8 m² total fire damper surface area in solid walls and ceiling slabs, lightweight partition walls as well as timber stud walls and half-timbered constructions
  • 4-fold arrangement up to 4.8 m² with common duct in solid walls, lightweight partition walls as well as timber stud walls and half-timbered constructions
  • Multiple occupancy up to 2.4 m² total fire damper surface area in solid walls and ceiling slabs, lightweight partition walls as well as timber stud walls and half-timbered constructions



Order code FK2-EU
FK2-EU1 – 7 / DE / 600 × 400 × 500 / ES / A0 / Z43
|||||||
1234567
1 Type
FK2-EU Fire damper

2 Construction
No entry: standard construction
1 Powder-coated casing, RAL 7001 (silver grey)
2 Stainless steel casing
7 Impregnated damper blade
1-7 Powder-coated casing, RAL 7001 (silver grey), ​and impregnated damper blade
2-7 Stainless steel casing and impregnated damper blade
W3 With fusible link 95 °C (only for use in warm air ventilation systems)
B4 With coated fusible link 72 °C
WB4 With coated fusible link 95 °C (only for use in warm air ventilation systems)

3 Country of destination
DE Germany
CH Switzerland
AT Austria
NL Netherlands
GB Great Britain
ES Spain
Other destination countries upon request

4 Nominal size [mm]
Specify width × height × length

5 Accessories 1
No entry: without accessories

ES
2

E3
1

EW
2

GM
2,3

WA
2

WE
2

GL100
2, 3

GL125
2, 3

GL150
2, 3

GL175
2, 3

6 Accessories 2
No entry: without accessories
0A – FR

7 Attachments
Z00 – ZA14

1
Only for FK2-EU with L = 305 mm

2
Only for FK2-EU with L = 500 mm

3
 Cannot be combined with Z...RM and ZA12

4
Only with attachments Z00 – Z03 and Z00EX – Z03EX

Order example: FK2-EU-W/DE/600×200×500/ES/A0/Z43

ConstructionGalvanised casing
Release temperature95 °C
Country of destinationGermany
Nominal size600 × 200 × 500 mm
Accessories 1Installation kit ES
Accessories 2Cover grille on operating side
AttachmentSpring return actuator 230 V AC




Order code FK2-EU with thermal insulation as ODA construction to prevent condensation
FK2-EU1-7-ODA/DE/600 × 400 × 500///Z43
|||||||
1234567
1 Type
FK2-EU Fire damper

2 Construction

1-7-ODA
1
Powder-coated casing, RAL 7001 (silver grey), ​impregnated damper blade and insulated damper casing (32 mm Armaflex Ultima)

3 Country of destination
DE Germany
CH Switzerland
AT Austria
NL Netherlands
GB Great Britain
ES Spain
Other destination countries upon request

4 Nominal size [mm]
Specify width × height × length

5 Accessories 1
No entry: without accessories2

6 Accessories2
No entry: without accessories3

7 Attachments
Z43, Z45, Z60, Z61, ZA07, ZL09, ZL10, ZL11, ZB01, ZA14

1
ODA with release temperature 72 °C only
2 ODA cannot be combined with accessories 1
3 Accessories 2 cannot be factory mounted, so please order separately

Order example: FK2-EU-1-7-ODA/600×200×500//ZA07
Construction variantCasing, powder-coated, silver grey (RAL 7001),
impregnated damper blade and insulated damper casing
(32 mm Armaflex Ultima)
Release temperature72 °C
Country of destinationGermany
Nominal size600 × 200 × 500 mm
Accessories 1None
Accessories 2None
AttachmentSpring return actuator 24 V and AS-EM




Order code for FK2-EU as an upstream shutter of an air transfer unit
FK2-EU1 – 7 / DE / 600 × 400 × 500 / ES / AA / Z01
|||||||
1234567
1 Type
FK2-EU Fire damper

2 Construction
No entry: standard construction
1 Powder-coated casing, RAL 7001 (silver grey)
2 Stainless steel casing
7 Impregnated damper blade
1-7 Powder-coated casing, RAL 7001 (silver grey), ​and impregnated damper blade
2-7 Stainless steel casing and impregnated damper blade

3 Country of destination
DE Germany
CH Switzerland
AT Austria
NL Netherlands
GB Great Britain
ES Spain
Other destination countries upon request

4 Nominal size [mm]
Specify width × height × length

5 Accessories 1
No entry: without accessories

ES
2

E3
1

EW
2

GM
2

GL100
2

GL125
2

GL150
2

GL175
2

6 Accessories 2
AA Cover grilles on both ends

7 Attachments
Z00 – ZB01

1
Only for FK2-EU with L = 305 mm
2 Only for FK2-EU with L = 500 mm
If the damper is to be used as an air transfer unit in Germany please note:
If a fire damper with only a mechanical shut-off element is to be used as an air transfer unit, the local building regulations apply. Such applications may require a building inspectorate licence. This has to be determined and applied for on a case to case basis (by others). Such air transfer units are usually only used for pressure differential systems.

Order example: FK2-EU/DE/200×200×500/AA/Z03

ConstructionGalvanised casing
Country of destinationGermany
Nominal size200 × 200 × 500 mm
Accessories 1None
Accessories 2Cover grilles on both ends
AttachmentLimit switches for damper blade positions OPEN and CLOSED



Order code FK2-EU as air transfer damper
FK2-EU1 – 7 / DE / 600 × 400 × 500 / ES / AA / Z43RM
|||||||
1234567
1 Type
FK2-EU Air transfer damper1

2 Construction
No entry: standard construction
1 Powder-coated casing, RAL 7001 (silver grey)
2 Stainless steel casing
7 Impregnated damper blade
1-7 Powder-coated casing, RAL 7001 (silver grey), ​and impregnated damper blade
2-7 Stainless steel casing and impregnated damper blade

3 Country of destination
DE Germany
CH Switzerland
AT Austria
NL Netherlands
GB Great Britain
ES Spain
Other destination countries upon request

4 Nominal size [mm]
Specify width × height × length

5 Accessories 1
No entry: without accessories
ES
E3
EW
GM2
GL1002
GL1252
GL1502
GL1752

6 Accessories 2
AA Cover grilles on both ends

7 Attachments
Z43RM, Z45RM, ZA12

1
For installation in Germany please note: The use as an air transfer damper has to comply with the general type approval
2 RM-O-3-D to be fixed with a bracket upstream or downstream of the damper

Order example: FK2-EU-1/DE/200×200×500/AA/Z43RM
Construction variantCasing powder-coated, RAL 7001, silver grey
Country of destinationGermany
Nominal size200 × 200 × 500 mm
Accessories 1Without
Accessories 2Cover grilles on both ends
AttachmentSpring return actuator 230 V AC with factory mounted and wired duct smoke detector RM-O-3-D as air transfer damper

Dimensions

  • DIMENSIONS

FK2-EU with fusible link 

Weight [kg] for casing length L = 305 [mm]/L = 500 [mm]

H

B

200

300

400

500

600

700

800

900

1000

1100

1200

1300

1400

1500

1004/55/66/87/98/119/1210/13
1504/65/77/98/109/1210/1311/15
2005/76/87/109/1210/1311/1512/1615/2016/2121/2723/2924/3126/3227/34
2507/98/1010/1211/1412/1614/1815/1916/2118/2324/2925/3127/3329/3530/38
3008/109/1211/1412/1513/1715/1916/2118/2319/2526/3228/3430/3632/3933/41
3508/1110/1311/1513/1715/1816/2018/2224/2926/3228/3430/3732/3934/4236/44
4009/1111/1312/1614/1816/2017/2219/2426/3128/3431/3733/3935/4237/4539/47
45010/1211/1413/1715/1917/2123/2826/3128/3430/3633/3935/4238/4540/4843/50
50010/1312/1514/1816/2018/2225/3027/3330/3633/3935/4236/4540/4843/5146/54
55015/1918/2221/2624/2826/3229/3532/3835/4137/4440/4743/5146/5449/57
60016/2019/2322/2725/3028/3331/3734/4037/4340/4743/5046/5349/5752/60
65017/2120/2523/2827/3230/3533/3936/4239/4642/4945/5348/5651/6055/63
70018/2221/2625/3028/3331/3735/4138/4441/4844/5248/5551/5954/6358/67
75019/2322/2726/3129/3533/3936/4340/4743/5047/5450/5854/6257/6661/70
80020/2424/2827/3331/3634/4038/4442/4945/5349/5753/6156/6560/6964/73

For more information on the constructions of the FK2-EU, see functional description.


ODA Construction

  • ODA CONSTRUCTION
FK2-EU with thermal insulation 

Supply package: FK2-EU with thermal insulation
① FK2-EU with thermal insulation on the operating side
② Insulating strips, Armaflex Ultima, around the perimeter


ODA construction

Application
  • Suitable for reducing condensation with outdoor air intake (ODA Outdoor air)
  • Only suitable for mortar-based installation with perimeter mortar infill


Materials and surfaces

  • Damper blade casing made of galvanised sheet steel, powder-coated (1)
  • Impregnated damper blade
  • Thermal insulation on the operating side made of 32 mm synthetic cellular rubber, fire rating class: B-s2-d0
  • Only in combination with spring return actuator (possible attachments Z43, Z45, Z60, Z61, ZA07, ZL09, ZL10, ZL11, ZB01, ZA14)

Note:
For further information relevant to design, in particular information on installation situations, please refer to the fire damper installation and operating manual and the additional installation manual for the ODA construction.

EASY INSTALLATION

FIRE DAMPER INSTALLATION IN A LIGHTWEIGHT PARTITION WALL

FIRE DAMPER INSTALLATION REMOTE FROM A LIGHTWEIGHT PARTITION WALL

SUBSEQUENT FIRE DAMPER INSTALLATION IN A LIGHTWEIGHT PARTITION WALL

FK2-EU: SIMPLE CONVERSION FROM THE OUTSIDE

MOUNTING LIMIT SWITCH

CONVERSION FROM SPRING RETURN ACTUATOR TO FUSIBLE LINK

CONVERSION FROM FUSIBLE LINK ACTUATOR TO SPRING RETURN

CONVERSION FROM FUSIBLE LINK TO SPRING RETURN ACTUATOR

CONVERSION FROM SPRING RETURN ACTUATOR TO FUSIBLE LINK

MOUNTING LIMIT SWITCH

DUCT MOUNTING FK2-EU (305MM LENGTH)

DOWNLOADS

product information

brochures

certificates

operation manuals

production {"X-Frame-Options"=>"SAMEORIGIN", "X-XSS-Protection"=>"1; mode=block", "X-Content-Type-Options"=>"nosniff", "X-Download-Options"=>"noopen", "X-Permitted-Cross-Domain-Policies"=>"none", "Referrer-Policy"=>"strict-origin-when-cross-origin", "Content-Security-Policy"=>"frame-ancestors 'self' https://api.scrivito.com https://punchoutcommerce.com https://www.trox.de https://trox-extern.com https://psp40.onventis.com https://psp22.onventis.com https://trox4u.troxgroup.com", "Strict-Transport-Security"=>"max-age=31536000; includeSubDomains", "Content-Type"=>"text/html; charset=utf-8"}

Share page

Recommend this page

Recommend this page by sending a link by mail.

Fields marked with an (*) are required fields.

Share page

Thank you for your recommendation!

Your recommendation has been sent and should arrive shortly.

Contact

We are here for you

Please specify your message and type of request
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265

Contact

We are here for you

Please specify your message and type of request
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265

Attachment (max. 10MB)

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265