FK2-EU   

For diverse applications

  • Nominal sizes 200 × 100 – 1500 × 800 mm, can be ordered in increments of 1 mm
  • Low differential pressure and sound power level
  • Explosion-proof construction (ATEX) as an option
  • Optionally available as an upstream shutter of an air transfer unit
  • Can also be used as an air transfer damper
  • Optional stainless steel casing or powder-coated casing for increased corrosion protection
  • Optionally available with thermal insulation to prevent condensation
  • Integration into the central BMS with TROXNETCOM
  • Universal installation options


Optional equipment and accessories
  • Electric actuator 24 V/230 V
  • Release temperature 72/95 °C  
     
Useful additions
  • Duct smoke detectors

Updating order code
Save configuration
Calculate price
Updating technical data
  • Media
Specification text:
Updating specification text
Show complete text Hide complete text
Initialize order code

General information

Application
  • Fire dampers with CE marking and declaration of performance, for the isolation of duct penetrations between two fire compartments in the event of a fire
  • To prevent the propagation of fire and smoke through ductwork to adjacent designated fire compartments



Special features
  • Declaration of performance in accordance with European Construction Products Regulation
  • Classification according to EN 13501-3, up to EI 240 (ve, ho, i ↔ o) S
  • Complies with the requirements of EN 15650
  • Tested for fire resistance properties in accordance with EN 1366-2 (300 Pa and 500 Pa negative pressure)
  • Certified mortar-based installation with reduced distances of 40 mm to supporting components or 60 mm between two fire dampers (flange to flange)
  • Perimeter gap may be up to 225 mm for mortar-based installation
  • 2 inspection accesses with bayonet fixing for single-handed operation
  • Meets the hygiene requirements of VDI 6022-1, VDI 3803-1, DIN 1946-4, EN 13779, of Ö-Norm H 6020 and H 6021, and of SWKI
  • Corrosion protection according to EN 15650 in connection with EN 60068-2-52
  • Closed blade air leakage to EN 1751, class 2
  • Casing air leakage to EN 1751, class C (B + H ≤700, class B)
  • Low differential pressure and sound power level
  • Any airflow direction
  • Integration into the central building management system with the international standard fire damper system in accordance with IEC 62026-2 with AS interface is possible


Classification
Performance class up to EN 13501-3, up to EI 240 (ve, ho, i ↔ o) S


Nominal sizes
  • B × H: 200 × 100 – 1500 × 800 mm (Intermediate sizes can be ordered in 1 mm increments)
  • L: 305 mm or 500 mm


Variants
  • With fusible link
  • With fusible link for use in potentially explosive atmospheres
  • With spring return actuator
  • With spring return actuator for use in potentially explosive atmospheres
  • With spring return actuator and duct smoke detector
  • With cover grille on both sides as an upstream shutter of an air transfer unit
  • With spring return actuator, duct smoke detector and cover grilles at both ends for use as an air transfer damper according to general building inspectorate licence Z-6.50-2540

The following applies to Germany:

If fire dampers with a purely mechanical shut-off element are to be used as an upstream shutter of an air transfer unit, the local building regulations must be observed. Usually the use of such upstream shutters of air transfer units is restricted to pressure differential systems.


Parts and characteristics
  • Release temperature 72 °C or 95 °C (for use in warm air ventilation systems)
  • Single-handed operation
  • Explosion-proof constructions for zones 1, 2, 21, 22


Attachments
  • Limit switch for damper blade position indication
  • Spring return actuator for 24 V AC/DC or 230 V AC supply voltage
  • Limit switch for damper blade position indication for use in potentially explosive atmospheres
  • Spring return actuator for 24 – 230 V supply voltage, for use in potentially explosive atmospheres
  • Network module for the integration with AS-i or LON networks
  • Spring return actuator and wired duct smoke detector with 230 VAC, 50/60 Hz or 24 VDC supply voltage
  • All attachments can be retrofitted


Accessories
  • Installation kit ES for dry mortarless installation in lightweight partition walls, compartment walls, safety partition walls and radiation protection walls with metal support structures or steel support structures, and cladding on both sides
  • Installation kit ES for dry mortarless installation in timber stud walls/half-timbered construction as well as solid wood and cross laminated timber walls
  • Installation kit ES for dry mortarless installation in shaft walls with metal support structure or steel support structure as well as shaft walls without metal support structure
  • Installation kit ES for dry mortarless installation in wooden beam ceilings and solid wood ceilings
  • Installation kit E3 for dry mortarless installation in solid walls in an existing installation subframe E1/E2 of the FK-K90 or FK-EU
  • Installation kit EW for dry mortarless installation in solid walls with installation subframe
  • Installation kit GM for installation into solid non-load-bearing walls with flexible ceiling joint
  • Installation kit WA for dry mortarless installation on the face of solid walls and ceiling slabs
  • Installation kit WE for dry mortarless installation remote from solid walls, remote from solid ceiling slabs, and remote from lightweight partition walls with metal support structure and cladding on both sides
  • Installation kit GL for dry mortarless installation in lightweight partition walls with metal support, cladding on both sides and flexible ceiling joint
  • Cover grille
  • Flexible connectors
  • Circular spigots
  • Profile connecting frame


Useful additions
  • Duct smoke detector RM-O-3-D
  • Duct smoke detector with airflow monitor RM-O-VS-D


Construction features
  • Rectangular or square construction, rigid casing, both flanges with fixing holes
  • Suitable for the connection of ducts, cover grilles, spigots, flexible connectors or profile connecting frames
  • The release mechanism is accessible and can be tested from the outside
  • 2 inspection access panels, Ø110 mm, which can be opened without any tools
  • Remote control with spring return actuator


Materials and surfaces

TROX casing:
  • Galvanised sheet steel
  • Galvanised sheet steel, powder-coated RAL 7001
  • Stainless steel 1.4301

Damper blade:
  • Special insulation material
  • Special insulation material with impregnation

ODA construction:
  • Damper casing made of galvanised sheet steel with powder coating and thermal insulation, damper blade made of special insulating material with impregnation (only in conjunction with spring return actuator)


Other components:
  • Damper blade shafts and drive linkage made of galvanised steel, in constructions -1 and -2 made of stainless steel
  • Plastic bearings
  • EPDM and TPE seals

The construction variants with stainless steel or powder-coated casing meet even more critical requirements for corrosion protection. Detailed listing on request.


Standards and guidelines
  • Construction Products Regulation
  • EN 15650 Ventilation for buildings – Fire dampers
  • EN 1366-2 Fire resistance tests for service installations – Fire dampers
  • EN 13501-3 Fire classification of construction products and building elements
  • EN 1751 Ventilation for buildings – Air terminal devices
  • 2006/42/EC – Machinery Directive


Supply package

If attachments and accessories are supplied from the factory with the fire dampers, they are already taken into account in the order code. Depending on the installation situations, supplementary materials for assembly and fixing may be needed to ensure proper installation, e.g. mortar, screws, mineral wool, etc. Such materials are not included in the supply package, unless they are expressly described as included in the supply package. The selection of additional attachments or accessories as well as the identification and provision of materials for assembly and fixing is the responsibility of those involved in the building project and must be done taking into account the required classification.




Maintenance
  • The functional reliability of the fire damper must be tested at least every six months; this has to be arranged by the owner of the ventilation system; functional tests must be carried out in compliance with the basic maintenance principles stated in EN 13306 and DIN 31051. If 2 consecutive tests, one 6 months after the other, are successful, the next test on the fire damper can be conducted one year later.
  • A functional test involves closing the damper blade and opening it again; with a spring return actuator this can be done via remote control
  • Fire dampers must be included in the regular cleaning schedule for the ventilation system
  • For details on functional tests, maintenance and inspection, refer to the installation and operating manual


Technical data
  • Nominal sizes: 200 × 100 to 1500 × 800 mm
  • Casing lengths: 305 and 500 mm
  • Volume flow rate range: up to 14400 l/s / up to 51840 m³/h
  • Differential pressure: up to 2000 Pa
  • Temperature range: -20 – 50 °C
  • Upstream velocity*: Standard construction ≤ 8 m/s, construction with spring return actuator ≤ 12 m/s, construction with explosion-proof actuator ExMax/RedMax-15-BF TR ≤ 10 m/s

* Data applies to uniform upstream and downstream conditions for the fire damper


Incorrect use:
  • Without specially approved attachments in areas with potentially explosive atmospheres
  • As a smoke control damper
  • Outdoors without sufficient protection against the effects of weather
  • In atmospheres where chemical reactions, whether planned or unplanned, may cause damage to the fire damper or lead to corrosion

The following applies to installation in Germany:
  • Do not use it in extract air systems in commercial kitchens
  • Use as air transfer damper only according to general type approval Z-6.50-2540
  • Do not use in combined penetration seal
  • Approvals under building regulations may be required for the use of upstream shutters of air transfer units. This must be checked and applied for by others
  • Flame-resistant building materials that form no dripping droplets (elastomer foams) have to be at least of fire rating class C - s2, d0 according to the German M‑VV TB (since 2019/01) guideline. The applicable national building regulations must be adhered to.

Technical information

Function, Technical Data, Quick sizing, Specification Text, Order Code

  • FUNCTION
  • TECHNICAL DATA
  • QUICK SIZING
  • SPECIFICATION TEXT
  • ORDER CODE

In the event of a fire, fire dampers shut automatically to prevent the propagation of fire and smoke through ductwork to adjacent designated fire compartments. In the event of a fire, the damper is triggered at 72 °C or at 95 °C (use in warm air ventilation systems) by a fusible link. The release mechanism is accessible and can be tested from the outside.

One or two limit switches (optional attachment) can be used to indicate the damper blade position.

 


Nominal sizes200 × 100 – 1500 × 800 mm ⁴
Casing lengths305 and 500 mm
Volume flow rate rangeUp to 14400 l/s or 51840 m³/h
Differential pressure rangeUp to 2000 Pa

Temperature range 1, 3

-20 to 50 °C
Release temperature72 °C or 95 °C (for warm air ventilation systems)
Upstream velocity ²

Standard construction ≤ 8 m/s,
Construction with spring return actuator ≤ 12 m/s,
Construction with explosion-proof actuator ExMax/RedMax-15-BF TR ≤ 10 m/s



¹ Temperatures may differ for units with attachments. Details for other applications are available on request.
² Data applies to uniform upstream and downstream conditions for the fire dampers.
³ Condensation and the intake of humid fresh air have to be avoided as otherwise operation will be impaired or not be possible.
⁴ Damper blade with lip seal for sizes 1 and 2, damper blade with travel stop seal for size 3.

Sizes see functional description


Free area and resistance coefficient, width 200 – 800 mm

H

(1)

B

200

250

300

350

400

450

500

550

600

650

700

750

800

100A [m²]0.0130.0160.020.0230.0270.030.0340.0370.0410.0440.0480.0510.055
100ζ1.050.960.880.830.780.750.710.690.660.640.620.610.59
125A [m²]0.01750.02220.0270.03170.03650.04120.0460.05070.05550.06020.0650.06970.0745
125ζ0.930.850.780.730.690.660.630.610.590.570.550.540.52
150A [m²]0.02210.02810.03410.04010.04610.05210.05810.06410.07010.07610.08210.08810.0941
150ζ0.850.770.710.670.630.60.580.550.540.520.50.490.48
160A [m²]0.0240.030.0370.0430.050.0560.0630.0690.0760.0820.0890.0950.102
160ζ0.660.60.550.520.490.470.450.430.410.40.390.380.37
200A [m²]0.0310.040.0480.0570.0650.0740.0820.0910.0990.1080.1160.1250.133
200ζ0.740.670.620.580.550.520.50.480.470.450.440.430.41
250A [m²]0.03970.05070.06170.07270.08370.09470.10570.11670.12770.13870.14970.16070.1717
250ζ0.670.610.560.530.50.470.450.440.420.410.40.380.37
300A [m²]0.04890.06240.07590.08940.10290.11640.12990.14340.15690.17040.18390.19740.2109
300ζ0.620.560.520.490.460.440.420.40.390.380.360.350.34
350A [m²]0.05810.07410.09010.10610.12210.13810.15410.17010.18610.20210.21810.23410.2501
350ζ0.580.520.480.450.430.410.390.380.360.350.340.330.32
400A [m²]0.06730.08580.10430.12280.14130.15980.17830.19680.21530.23380.25230.27080.2893
400ζ0.540.490.460.430.40.390.370.350.340.330.320.310.3
450A [m²]0.07650.09750.11850.13950.16050.18150.20250.22350.24450.23550.25480.27410.2934
450ζ0.570.510.470.430.410.390.370.350.340.330.320.310.3
500A [m²]0.08570.10920.13270.15620.17970.20320.22670.25020.27370.2660.28780.30960.3314
500ζ0.540.480.440.410.390.370.350.340.330.310.30.30.29
550A [m²]0.12640.15070.1750.19930.22360.24790.27220.29650.32080.34510.3694
550ζ0.420.40.370.350.340.320.310.30.290.280.28
600A [m²]0.13940.16620.1930.21980.24660.27340.30020.3270.35380.38060.4074
600ζ0.410.380.360.340.320.310.30.290.280.270.27
650A [m²]0.15240.18170.2110.24030.26960.29890.32820.35750.38680.41610.4454
650ζ0.390.370.350.330.310.30.290.280.270.260.26
700A [m²]0.16540.19720.2290.26080.29260.32440.35620.3880.41980.45160.4834
700ζ0.380.350.330.320.30.290.280.270.260.250.25
750A [m²]0.17840.21270.2470.28130.31560.34990.38420.41850.45280.48710.5214
750ζ0.370.340.320.310.290.280.270.260.250.250.24
800A [m²]0.19140.22820.2650.30180.33860.37540.41220.4490.48580.52260.5594
800ζ0.360.330.320.30.290.270.260.260.250.240.23

(1) Parameter


Free area and resistance coefficient, width 850 – 1500 mm

H

Parameter

B

900

1000

1100

1200

1300

1400

1500

200

A [m²]

0.117

0.1665

0.1442

0.1578

0.1714

0.185

0.1986

200

ζ

0.44

0.42

0.40

0.39

0.38

0.36

0.35

250

A [m²]

0.16

0.2157

0.1972

0.2158

0.2344

0.253

0.2716

250

ζ

0.39

0.37

0.35

0.34

0.33

0.32

0.31

300

A [m²]

0.203

0.2649

0.2502

0.2738

0.2974

0.321

0.3446

300

ζ

0.35

0.34

0.32

0.31

0.30

0.29

0.28

350

A [m²]

0.246

0.2746

0.3032

0.3318

0.3604

0.389

0.4176

350

ζ

0.32

0.31

0.30

0.29

0.28

0.27

0.26

400

A [m²]

0.289

0.3226

0.3562

0.3898

0.4234

0.457

0.4906

400

ζ

0.30

0.29

0.28

0.27

0.26

0.25

0.25

450

A [m²]

0.332

0.3706

0.4092

0.4478

0.4864

0.525

0.5636

450

ζ

0.29

0.28

0.26

0.26

0.25

0.24

0.23

500

A [m²]

0.375

0.4186

0.4622

0.5058

0.5494

0.593

0.6366

500

ζ

0.27

0.26

0.25

0.24

0.24

0.23

0.22

550

A [m²]

0.418

0.4666

0.5152

0.5638

0.6124

0.661

0.7096

550

ζ

0.26

0.25

0.24

0.23

0.23

0.22

0.21

600

A [m²]

0.461

0.5146

0.5682

0.6218

0.6754

0.729

0.7826

600

ζ

0.25

0.24

0.23

0.22

0.22

0.21

0.20

650

A [m²]

0.504

0.5626

0.6212

0.6798

0.7384

0.797

0.8556

650

ζ

0.24

0.23

0.22

0.22

0.21

0.20

0.20

700

A [m²]

0.547

0.6106

0.6742

0.7378

0.8014

0.865

0.9286

700

ζ

0.24

0.23

0.22

0.21

0.20

0.20

0.19

750

A [m²]

0.59

0.6586

0.7272

0.7958

0.8644

0.933

1.0016

750

ζ

0.23

0.22

0.21

0.20

0.20

0.19

0.19

800

A [m²]

0.633

0.7066

0.7802

0.8538

0.9274

1.01

1.0746

800

ζ

0.22

0.21

0.20

0.20

0.19

0.19

0.18

① Parameter 


Quick sizing tables provide a good overview of the volume flow rates with different sound power levels as well as of differential pressures of up to 35 Pa. Approximate intermediate values can be interpolated. Precise intermediate values can be calculated with our Easy Product Finder design program. You can find this on our website at: 
www.trox.de/mytrox/auslegungsprogramm-easy-poduct-finder-182e16348fac3d33


Volume flow rate qv in [m³/h] for differential pressure Δpst 35 Pa
200 – 650 mm

H

LWA [dB(A)]

B

200

250

300

350

400

450

500

550

600

650

10035390484577668759849938102711161205
1253550762774586297810931208132214351548
150356197649071048118813261464160117371873
1603572889710631227139015501710186920272185
20035835102812161402158617691950213023092487
250351026126414961725195121742396261628353053
300351232151217862056232125842844310333603615
350351434175720712379268329843281357738704161
400351634199723512698303933773710404143694696
450351474185622252585293832863629396943054640
500351647207124802878326936524031440647785146
5503527333169359540154429483852435645
6003529833456391943744823526657046139
6503532323742424147305213568961606627
7003534794026456050845600610966137112
7503537254308487754355984652670627592
8003539704589519357846367694175088070


Volume flow rate qv in [m³/h] for differential pressure Δpst 35 Pa
700 – 1500 mm

H

LWA [dB(A)]

B

700

750

800

900

1000

1100

1200

1300

1400

1500

100

35

1293

1380

1468

125

35166017721883
15035200821422276
16035234124972653
200352664284130172633291531963476375440314308
250353270348637013422378541474506486452215576
300353869412243744172461150485482591563456774
350354451473950274895540659146419692274237922
400355020534356645597617767537327789784659031
4503549725302563062826929757282118847948010110
50035551258756237695576678374907797761047111164
550356044644068347616839291629926106871144412198
6003565706998742482699107993810763115841240113214
65035709175518008891498131070411589124691334414216
700357606809885859553105111146112405133431427615204
7503581188640915810186112031221113213142081519716181
8003586269178972710813118891295514013150641610917149


Volume flow rate qv in [m³/h] for differential pressure Δpst 35 Pa
200 – 650 mm

H

LWA [dB(A)]

B

200

250

300

350

400

450

500

550

600

650

100

45

525

690

841

975

1107

1239

1369

1499

1629

1758

125

45

710

870

1088

1258

1427

1595

1762

1928

2094

2258

150

45

880

1115

1323

1529

1733

1935

2136

2336

2534

2732

160451063130915521791202822622496272729583188
200451219149917752046231425802845310733683628
250451498184421832517284631733496381841374455
300451797220726072999338737704150452749025274
350452092256330223472391543544788521856466071
400452384291534313937443549275413589663756851
450452151270932473772428747945295579062826769
500452404302236194200476953295882642969717508
5504539874623524658586462705976508237
6004543535043571863827036768383228957
6504547155460618769027605830089889669
70045507658746653741881708913964810376
750455435628671167930873195221030311077
8004557926695757684409289101271095411774


Volume flow rate qv in [m³/h] for differential pressure Δpst 35 Pa
700 – 1500 mm

H

LWA [dB(A)]

B

700

750

800

900

1000

1100

1200

1300

1400

1500

10045188620142142
12545242225852748
15045292931263322
16045341636443871
200453887414544023842425446635071547758826285
250454771508654004993552360506575709776178136
300455645601463826088672873657999863092589884
350456494691573347142788886299366101001083011558
4004573247795826481669012985310690115221235113177
450457254773582149166101101104811980129081383114751
5004580428572910010147111861221713243142631527816289
5504588189397997111113122441336714483155931669717797
600459586102111083212065132871449915704169021809319280
6504510345110161168313006143171561716908181921947020741
7004511098118141252613938153361672218099194672082822183
7504511844126061336214861163451781619277207292217223609
8004512586133911419115777173461890120444219782350325020

The Easy Product Finder allows you to size products using your project-specific data. You will find the Easy Product Finder on our website.

Sizing example

Given data           Quick sizing
Volume flow rate: 3350 m³/h         FK2-EU/400×300×500
Maximum width: 300 mm
Sound power level: 45 dB(A)


Specification text

Fire damper in line with the European product standard DIN EN 15650 in square or rectangle construction style with two large inspection accesses that can be operated without tools. Tested for fire resistance properties according to DIN EN 1366-2 (300 Pa and 500 Pa negative pressure), with CE label.

The fire damper manufacturer's declaration of performance (DoP) provides proof that a product is suitable for the respective installation conditions, e.g. in, on the face of and remote from walls or ceilings, with the stated essential characteristics such as size, supporting construction, construction and installation type, and that it has the corresponding class of performance to EN 13501-3.

The ready-for-operation unit includes a release mechanism and a replaceable, fire-resistant damper blade, which, depending on the application, can be either horizontal or vertical. Depending on application, classified from:

EI 30 (ve, ho i ↔ o) S to EI 240 (ve, ho i ↔ o) S

 

Suitable for:

Mortar-based installation
  • In solid walls, walls made from gypsum wall boards, lightweight partition walls, compartment walls, safety partition walls and walls to provide radiation protection
  • In solid walls with partial mortaring
  • With installation kit for flexible ceiling joints in solid walls
  • In shaft walls with metal support structures or steel support structures
  • In timber stud walls and timber frame walls, as well as solid wood and cross laminated timber walls
  • In and on solid walls and in combination with timber beam, solid wood and modular ceilings (System Cadolto)
  • In solid wood ceilings, wooden beam ceilings and historical wooden beam ceilings
  • Multiple occupancy up to 4.8 m² total fire damper surface area in solid walls and ceiling slabs, lightweight partition walls as well as timber stud walls and half-timbered constructions
  • Combined installation with FKRS-EU and FKR-EU in solid walls and ceiling slabs, lightweight partition walls, shaft walls as well as timber stud walls and half-timbered constructions up to 1.2 m² total fire damper surface area
  • In lightweight partition walls, compartment walls, safety partition walls and radiation protection walls with metal support structures or steel support structures
  • 4-fold arrangement up to 4.8 m² total fire damper surface area with common duct in solid walls, lightweight partition walls as well as timber stud walls and half-timbered constructions
  • Mortar-based installation in concrete base on solid ceiling slabs, also combined with FKRS-EU and FKR-EU as well as multiple occupancy up to 4.8 m² total fire damper surface area
  • In hollow-stone, hollow-section, ribbed and composite ceiling slabs

 

Dry mortarless installation
  • In lightweight partition walls, compartment walls, safety partition walls and radiation protection walls with metal support structures or steel support structures
  • In lightweight partition walls with metal support structure and cladding on both sides, and with flexible ceiling joint
  • In timber stud walls and timber frame walls, as well as solid wood and cross laminated timber walls
  • In solid walls with installation kit E3 in an existing installation subframe E1/E2 of the FK-K90 or FK-EU
  • In solid walls with installation kit EW and installation subframe
  • With gypsum board/gypsum plaster fire protection panels in lightweight partition walls with metal support
  • With mineral wool in lightweight partition wall with metal support, timber stud walls and half-timbered constructions as well as solid wood walls
  • In shaft walls with metal support structure or steel support structure, and in shaft walls without metal support structure
  • In solid wood and wooden beam ceilings
  • With an installation kit on the face of and remote from solid walls and ceiling slabs
  • Remote from lightweight partition walls (wall penetration)


Fire batt installation
  • In solid walls and ceiling slabs
  • In lightweight partition walls, compartment walls, safety partition walls and walls to provide radiation protection, with metal support structure or steel support structure
  • In timber stud walls, half-timbered constructions, solid wood walls and CLT walls
  • Multiple occupancy up to 2.4 m² total fire damper surface area in solid walls and ceiling slabs, lightweight partition walls as well as timber stud walls and half-timbered constructions


Size dimensions from (B × H) 200 mm × 100 mm – 1500 mm × 800 mm, intermediate sizes can be ordered in 1 mm increments. Optimised low-leakage casing, up to leakage class C to EN 1751 with low differential pressure and low sound power level. Fire damper casing made of galvanised sheet steel, optionally galvanised sheet steel with powder coating RAL 7001 or stainless steel 1.4301. Damper blade made of special insulation material; coating as an option.

Corrosion protection according to EN 15650 in connection with EN 60068-2-52. Hygienic requirements are fulfilled in accordance with VDI 6022-1, VDI 3803-1, DIN 1946-4, DIN EN 13779 as well as the Önorm H 6020 and H 6021 and the SWKI. Casing length 305 mm or 500 mm with a 30 mm (L = 500 mm) flange for the connection to ducts made of non-combustible or combustible materials. Thermal release at 72 °C or 95 °C (warm air ventilation systems) with a fusible link or thermoelectrically with a spring return actuator, push button and indicator light (LED). Constructions with a brushless actuator for opening and closing the fire damper, also when the ventilation system is running and independent of the nominal size, are particularly suitable for functional checks and for shutting off sections of the duct system. Retrofit of spring return actuators without modification of the rod is possible from the outside. Explosion-proof constructions for zones 1, 2, 21 and 22 available with limit switch or spring return actuator.

In the version with thermal insulation made of 32 mm synthetic cellular rubber, fire rating class: B-s2-d0, spring return actuator and perimeter mortar infill, suitable for reducing condensation in the case of outdoor air intake (ODA Outdoor air)


Special features
  • Declaration of performance in accordance with European Construction Products Regulation
  • Classification to EN 13501-3, to EI 240 (ve, ho, i ↔ o) S
  • Complies with the requirements of EN 15650
  • Tested for fire resistance properties in accordance with EN 1366-2 (300 Pa and 500 Pa negative pressure)
  • Certified mortar-based installation with reduced distances of 40 mm to supporting components or 60 mm between two fire dampers (flange to flange)
  • Perimeter gap may be up to 225 mm for mortar-based installation
  • 2 inspection accesses with bayonet fixing for single-handed operation
  • Meets the hygiene requirements of VDI 6022-1, VDI 3803-1, DIN 1946-4, EN 13779, of Ö-Norm H 6020 and H 6021, and of SWKI
  • Corrosion protection according to EN 15650 in connection with EN 60068-2-52
  • Closed blade air leakage to EN 1751, class 2
  • Casing air leakage to EN 1751, class C (B + H ≤700, class B)
  • Low differential pressure and sound power level
  • Any airflow direction
  • Integration into the central building management system with the international standard fire damper system in accordance with IEC 62026-2 with AS interface is possible


Technical data
  • Nominal sizes: 200 × 100 to 1500 × 800 mm
  • Casing lengths: 305 and 500 mm
  • Volume flow rate range: up to 14400 l/s / up to 51840 m³/h
  • Differential pressure: up to 2000 Pa
  • Temperature range: -20 – 50 °C
  • Upstream velocity*: Standard construction ≤ 8 m/s, construction with spring return actuator ≤ 12 m/s, construction with explosion-proof actuator ExMax/RedMax-15-BF TR ≤ 10 m/s

* Data applies to uniform upstream and downstream conditions for the fire damper


Materials and surfaces

TROX casing:
  • Galvanised sheet steel
  • Galvanised sheet steel, powder-coated RAL 7001
  • Stainless steel 1.4301

Damper blade:

  • Special insulation material
  • Special insulation material with impregnation


ODA construction:

  • Damper casing made of galvanised sheet steel with powder coating and thermal insulation, damper blade made of special insulating material with impregnation (only in conjunction with spring return actuator)

Other components:

  • Damper blade shafts and drive linkage made of galvanised steel, in constructions -1 and -2 made of stainless steel
  • Plastic bearings
  • EPDM and TPE seals


The construction variants with stainless steel or powder-coated casing meet even more critical requirements for corrosion protection. Detailed listing on request.


Equivalence criteria
  • The declaration of performance according to the Construction Products Regulation describes all CE-certified installation types including the performance class up to EI 240 S according to EN 13501-3 as well as the essential characteristics of at least the
  • Hygienic requirements are fulfilled in accordance with VDI 6022-1, VDI 3803-1, DIN 1946-4, DIN EN 13779 as well as the Önorm H 6020 and H 6021 and the SWKI.
  • CE-marked and thus tested for fire protection according to EU regulation 305/2011 and evaluated according to machinery directive 2006/42/EC
  • CE-certified mortar-based installation at a distance ≥ 60mm between 2 fire dampers (flange to flange)
  • Combined installation with FKRS-EU and FKR-EU in solid walls and ceiling slabs, lightweight partition walls, shaft walls as well as timber stud walls and half-timbered constructions up to 1.2 m² total fire damper surface area
  • 2 inspection access panels Ø110 mm, with bayonet fixing (can be opened without tools)
  • Pressure loss < 15 Pa at reference size 400 × 200 mm and 6 m/s face velocity
  • Sound power < 38 dB (A) at reference size 400 × 200 mm and 6 m/s face velocity
  • Multiple occupancy up to 4.8 m² total fire damper surface area in solid walls and ceiling slabs, lightweight partition walls as well as timber stud walls and half-timbered constructions
  • 4-fold arrangement up to 4.8 m² with common duct in solid walls, lightweight partition walls as well as timber stud walls and half-timbered constructions
  • Multiple occupancy up to 2.4 m² total fire damper surface area in solid walls and ceiling slabs, lightweight partition walls as well as timber stud walls and half-timbered constructions



Order code FK2-EU

FK2-EU1 – 7 / DE / 600 × 400 × 500 / ES / A0 / Z43
|||||||
1234567
1 Type
FK2-EU Fire damper
 
2 Construction
No entry required: standard construction
powder-coated casing RAL 7001
2 stainless steel casing
7 impregnated damper blade
1 – 7 powder-coated casing RAL 7001 ​and impregnated damper blade
2 – 7 stainless steel casing and impregnated damper blade
Wwith fusible link 95 °C
(only for use in warm air ventilation systems)
B4 with coated fusible link 72 °C
WB4 with coated fusible link 95 °C
(only for use in warm air ventilation systems)
 
3 Country of destination
DE Germany
CH Switzerland
AT Austria
NL Netherlands
GB Great Britain
ES Spain
Other countries of destination upon request
 
4 Nominal size [mm]
B × H × L
 
5 Accessories 1
No entry required: none
ES2
E31
EW2
GM2, 3
WA2
WE2
GL1002, 3
GL1252, 3
GL1502, 3
GL1752, 3
 
6 Accessories 2
No entry required: none
0A – FR
 
7 Attachments

Z00 – ZA14
 
1 Only for FK2-EU with L = 305 mm
2 Only for FK2-EU with L = 500 mm
3 Not combinable with Z...RM and ZA12
4 Only for attachments Z00 – Z03 and Z00EX – Z03EX

Order example: FK2-EU-W/DE/600×200×500/ES/A0/Z43
Construction variantCasing, galvanised
Release temperature95 °C
Country of destinationGermany
Nominal size600 × 200 × 500 mm
Accessories 1Installation kit ES
Accessories 2Cover grille on operating side
AttachmentSpring return actuator 230 V AC



Order code FK2-EU with thermal insulation as ODA construction to prevent condensation

FK2-EU1-7-ODA/DE/600 × 400 × 500///Z43
|||||||
1234567
1 Type
FK2-EU Fire damper
 
2 Construction

1-7-ODA1 powder-coated housing RAL 7001, impregnated damper blade and insulated damper housing (32 mm Armaflex Ultima)
 
3 Country of destination
DE Germany
CH Switzerland
AT Austria
NL Netherlands
GB Great Britain
ES Spain
Other countries of destination upon request
 
4 Nominal size [mm]
B × H × L
 
5 Accessories 1
No entry required: none2
 
6 Accessories 2 
No entry required: none3
 
7 Attachments

Z43, Z45, Z60, Z61, ZA07, ZL09, ZL10, ZL11, ZB01, ZA14
 
1 ODA only with 72 °C release temperature
2 ODA cannot be combined with accessories 1
3 Accessories 2 cannot be factory mounted, when needed please order separately when needed

Order example: FK2-EU-1-7-ODA/600×200×500//ZA07
Construction variantCasing, powder-coated, silver grey (RAL 7001),
impregnated damper blade and insulated damper casing
(32 mm Armaflex Ultima)
Release temperature72 °C
Country of destinationGermany
Nominal size600 × 200 × 500 mm
Accessories 1None
Accessories 2None
AttachmentSpring return actuator 24 V and AS-EM



Order code for FK2-EU as an upstream shutter of an air transfer unit

FK2-EU1 – 7 / DE / 600 × 400 × 500 / ES / AA / Z01
|||||||
1234567
1 Type
FK2-EU Fire damper
 
2 Construction

No entry required: standard construction
powder-coated casing RAL 7001
2 stainless steel casing
7 impregnated damper blade
1 – 7 powder-coated casing RAL 7001 ​and impregnated damper blade
2 – 7 stainless steel casing and impregnated damper blade
 
3 Country of destination
DE Germany
CH Switzerland
AT Austria
NL Netherlands
GB Great Britain
ES Spain
Other countries of destination upon request
 
4 Nominal size [mm]

B × H × L
 
5 Accessories 1
No entry required: none
ES2
E31
EW2
GM2
GL1002
GL1252
GL1502
GL1752
 
6 Accessories 2

AA Cover grilles on both ends
 
7 Attachments

Z00 - ZB01
 
1 Only for FK2-EU with L = 305 mm
2 Only for FK2-EU with L = 500 mm
 
For Germany, the following applies when used as an upstream shutter of an air transfer unit:
If fire dampers with a purely mechanical shut-off element are to be used as an air transfer unit, the local building regulations must be observed. This may require building authority approvals. This must be checked and applied for by others. Usually the use of such upstream shutters of air transfer units is restricted to pressure differential systems.

Order example: FK2-EU/DE/200×200×500/AA/Z03
Construction variantCasing, galvanised
Country of destinationGermany
Nominal size200 × 200 × 500 mm
Accessories 1None
Accessories 2Cover grilles on both ends
AttachmentLimit switches for damper blade positions OPEN and CLOSED



Order code FK2-EU as air transfer damper

FK2-EU1 – 7 / DE / 600 × 400 × 500 / ES / AA / Z43RM
|||||||
1234567
1 Type
FK2-EU Air transfer damper1
 
2 Construction

No entry required: standard construction
powder-coated casing RAL 7001
2 stainless steel casing
7 impregnated damper blade
1 – 7 powder-coated casing RAL 7001 ​and impregnated damper blade
2 – 7 stainless steel casing and impregnated damper blade
 
3 Country of destination
DE Germany
CH Switzerland
AT Austria
NL Netherlands
GB Great Britain
ES Spain
Other countries of destination upon request
 
4 Nominal size [mm]
B × H × L
 
5 Accessories 1
No entry required: none
ES
E3
EW
GM2
GL1002
GL1252
GL1502
GL1752
 
6 Accessories 2
AA Cover grilles on both ends
 
7 Attachments
Z43RM, Z45RM, ZA12
 
1 The following applies to Germany:
Use of the air transfer damper according to the specifications of the general type approval
2 Mounting the RM-O-3-D via console in front of or behind the damper blade

Order example: FK2-EU-1/DE/200×200×500/AA/Z43RM
Construction variantCasing powder-coated, RAL 7001, silver grey
Country of destinationGermany
Nominal size200 × 200 × 500 mm
Accessories 1Without
Accessories 2Cover grilles on both ends
AttachmentSpring return actuator 230 V AC with factory mounted and wired duct smoke detector RM-O-3-D as air transfer damper

Dimensions, ODA construction

  • DIMENSIONS
  • ODA CONSTRUCTION

H

B

200

300

400

500

600

700

800

900

1000

1100

1200

1300

1400

1500

100 4/5 5/6 6/8 7/9 8/11 9/12 10/13
150 4/6 5/7 7/9 8/10 9/12 10/13 11/15
200 5/7 6/8 7/10 9/12 10/13 11/15 12/16 15/20 16/21 21/27 23/29 24/31 26/32 27/34
250 7/9 8/10 10/12 11/14 12/16 14/18 15/19 16/21 18/23 24/29 25/31 27/33 29/35 30/38
300 8/10 9/12 11/14 12/15 13/17 15/19 16/21 18/23 19/25 26/32 28/34 30/36 32/39 33/41
350 8/11 10/13 11/15 13/17 15/18 16/20 18/22 24/29 26/32 28/34 30/37 32/39 34/42 36/44
400 9/11 11/13 12/16 14/18 16/20 17/22 19/24 26/31 28/34 31/37 33/39 35/42 37/45 39/47
450 10/12 11/14 13/17 15/19 17/21 23/28 26/31 28/34 30/36 33/39 35/42 38/45 40/48 43/50
500 10/13 12/15 14/18 16/20 18/22 25/30 27/33 30/36 33/39 35/42 36/45 40/48 43/51 46/54
550 15/19 18/22 21/26 24/28 26/32 29/35 32/38 35/41 37/44 40/47 43/51 46/54 49/57
600 16/20 19/23 22/27 25/30 28/33 31/37 34/40 37/43 40/47 43/50 46/53 49/57 52/60
650 17/21 20/25 23/28 27/32 30/35 33/39 36/42 39/46 42/49 45/53 48/56 51/60 55/63
700 18/22 21/26 25/30 28/33 31/37 35/41 38/44 41/48 44/52 48/55 51/59 54/63 58/67
750 19/23 22/27 26/31 29/35 33/39 36/43 40/47 43/50 47/54 50/58 54/62 57/66 61/70
800 20/24 24/28 27/33 31/36 34/40 38/44 42/49 45/53 49/57 53/61 56/65 60/69 64/73
FK2-EU with thermal insulation FK2-EU_gc_250ai.png

Supply package: FK2-EU with thermal insulation
① FK2-EU with thermal insulation on the operating side
② Insulating strips, Armaflex Ultima, around the perimeter

Application
  • Suitable for reducing condensation with outdoor air intake (ODA Outdoor air)
  • Only suitable for mortar-based installation with perimeter mortar infill

Materials and surfaces
  • Damper blade casing made of galvanised sheet steel, powder-coated (1)
  • Impregnated damper blade
  • Thermal insulation on the operating side made of 32 mm synthetic cellular rubber, fire rating class: B-s2-d0
  • Only in combination with spring return actuator (possible attachments Z43, Z45, Z60, Z61, ZA07, ZL09, ZL10, ZL11, ZB01, ZA14)


Note:

For further information relevant to design, in particular information on installation situations, please refer to the fire damper installation and operating manual and the additional installation manual for the ODA  construction.

Accessories and Attachments

  • ACCESSORIES 1
  • ACCESSORIES 2
  • ATTACHMENT

Accessories 1 - Installation kits

Installation kit ES 

Application

  • Universally applicable installation kit for dry mortarless installation 
  • In lightweight partition walls, compartment walls, safety partition walls and radiation protection walls with metal support structures or steel support structures 
  • In timber stud walls and timber frame walls, as well as solid wood and cross laminated timber walls 
  • In shaft walls with metal support structure or steel support structure, and in shaft walls without metal support structure 
  • In solid wood and wooden beam ceilings 

Notes
  • Fire dampers with installation kit only with casing length L = 500 mm 
  • The installation kit must be mounted on the fire damper by others 
  • The installation kit can also be ordered and supplied separately 
  • Enough clear space is required for installation of the installation kit 
  • For further information relevant to design, in particular information on installation situations, please refer to the operating and installation manual. 

L

Order code

500

ES


Installation kit E3 

Application 

  • FK2-EU with installation kit E3 for exchanging an existing FKK90 or FK-EU with installation subframe E1 or E2 embedded in mortar 

Requirement 
  • The installation subframe E1/E2 has been installed in the solid wall according to general building inspectorate licence (FK-K90) or the installation and operating manual (FK-EU) 

Note 
  • Fire damper FK2-EU and installation kit E3 are ordered together. The FK2-EU (structural length 305 mm) is supplied with 2 extension pieces (70 and 125 mm), meaning that an FK-K90 / FK-EU can be exchanged without changes to the connected ducts
  • The installation kit must be mounted on the fire damper by others  
  • The installation kit E3 can also be ordered and supplied separately if required, in which case the extension pieces on the fire damper (70 and 125 mm) must be ordered by others   
  • Enough clear space is required for installation of the installation kit 
  • For further information relevant to design, in particular information on installation situations, please refer to the operating and installation manual.

L

Order code

305 mm with V parts over 500 mm

E3


Installation kit EW 

Application

  • Installation kit EW for dry mortarless installation in an installation subframe embedded in mortar 

Requirement 
  • The installation subframe has been installed in the solid wall with perimeter mortar infill

Note 
  • Fire dampers with installation kit only with casing length L = 500 mm 
  • The installation kit must be mounted on the fire damper by others  
  • The installation kit and installation subframe can also be ordered and supplied separately 
  • Enough clear space is required for installation of the installation kit  
  • For further information relevant to design, in particular information on installation situations, please refer to the operating and installation manual.

L

Order code

500

EW




Installation kit GM 

Application 

  • Installation kit for installation into solid non-load-bearing internal walls with flexible ceiling joint. With the installation kit the fire damper may be installed just below the movement joint; the joint is not interrupted by the installation kit 

Note 
  • Fire dampers with installation kit only with casing length L = 500 mm
  • Installation only with horizontal damper blade 
  • The installation kit can also be ordered and supplied separately  
  • Enough clear space is required for installation of the installation kit  
  • For further information relevant to design, in particular information on installation situations, please refer to the operating and installation manual 

L

Order code

500

GM



Installation kit WA 

Application 

  • Installation kit for Installation on the face of solid walls and ceiling slabs 

Note 
  • Fire dampers with installation kit only with casing length L = 500 mm 
  • The installation kit must be mounted on the fire damper by others 
  • The installation kit can also be ordered and supplied separately  
  • Enough clear space is required for installation of the installation kit  
  • The supplied anchor bolts are suitable for mounting on solid concrete walls and ceilings. Alternatively, equivalent anchor bolts must be provided, with suitability certificate for fire resistance provided by others, matched to the wall / ceiling slab or push through installation 
  • For further information relevant to design, in particular information on installation situations, please refer to the operating and installation manual.

L

Order code

500

WA


Installation kit WE 

Application

  • Installation kit for installation remote from solid walls and ceiling slabs, and remote from lightweight partition walls with cladding on both sides 

Note 
  • Fire dampers with installation kit only with casing length L = 500 mm
  • The installation kit must be mounted on the fire damper by others 
  • The installation kit can also be ordered and supplied separately  
  • Connection of the fire damper to ducts made of galvanised or stainless steel (to be provided by others) 
  • Fire-resistant cladding made of panel material (provided by others) 
  • Enough clear space is required for installation of the installation kit  
  • For further information relevant to design, in particular information on installation situations, please refer to the operating and installation manual.

L

Order code

500

WE


Installation kit GL 

Application 

  • Installation kit for installation in lightweight partition walls with metal support and cladding on both sides with flexible ceiling joint (dry mortarless installation) directly underneath solid ceiling slabs 

Note 
  • Fire dampers with installation kit only with casing length L = 500 mm 
  • The installation kits are adapted to the wall thickness or the width of the metal stud system  
  • GL100 for wall thickness 100 mm when using 50 mm profile width 
  • GL125 for wall thickness 125 mm when using 75 mm profile width 
  • GL150 for wall thickness 150 mm when using 100 mm profile width 
  • GL175 for wall thickness 175 mm when using 125 mm profile width  
  • Drive side on the right (details for a different installation orientation are available upon request)
  •  The installation kit must be mounted on the fire damper by others The installation kit can also be ordered and supplied separately  
  • Enough clear space is required for installation of the installation kit  
  • For further information relevant to design, in particular information on installation situations, please refer to the operating and installation manual.

L

Order code

500

GL100
GL125
GL150
GL175


Accessories 2 – Cover grille

Application 

  • If only one end is to be ducted on site, the other end must have a cover grille. If no duct is connected (upstream shutter of an air transfer unit or air transfer damper), cover grilles must be provided at both ends

Note 
  • Extension pieces are required for heights > 400 mm due to construction 
  • Fire damper, cover grille and, if applicable, extension piece are factory assembled to form a unit 
  • The free area of the cover grille is approx. 70 % 
  • The fixing holes in the cover grille and extension piece match those in the fire damper flanges 
  • Cover grilles are also available separately 
  • When using the FK2-EU as an air transfer damper in accordance with general building inspectorate licence Z-6.50-2540, cover grilles must be provided at both ends 
  • When using the FK2-EU as upstream shutter of an air transfer unit, cover grilles must be provided at both ends 
  • For further information relevant to design, in particular information on installation situations, please refer to the operating and installation manual. 

Materials and surfaces 
  • Cover grilles and extension pieces (height-dependent) made of galvanised sheet steel (and powder-coated silver grey, RAL 7001, when used with powder-coated (1) and stainless steel (2) dampers) 
  • Mesh aperture 10 mm × 10 mm, wire width 2 mm 

The following applies to Germany: 
  • Use as air transfer damper with cover grilles at both ends, spring return actuator and duct smoke detector according to general building inspectorate licence: Z-6.50-2540 
  • If fire dampers are used as upstream shutters of air transfer units, the national building regulations must be observed. Usually the use of such upstream shutters of air transfer units is restricted to pressure differential systems

Operating side

Installation side

Order code

Casing length

Cover grille A0

305/500

Cover grille 0A

500

Cover grille Cover grille AA *

500

Cover grille Flexible connector AS

500

Flexible connector Cover grille SA

500

Cover grille Circular spigot AR

500

Circular spigot Cover grille RA

500

Cover grille Profile connecting frame AF

305/500

Profile connecting frame Cover grille FA

500

* AA for FK2-EU as upstream shutter of an air transfer unit and air transfer damper according to general building inspectorate licence Z-6.50-2540.


Accessories 2 – Flexible connector

Application

  • To limit forces due to ducts expansions and wall deformations in the event of a fire, we recommend using flexible connectors for installation in lightweight partition walls, shaft walls and lightweight compartment walls, as well as fire batt installation
Note
  • Be sure to comply with the relevant national guidelines on limiting forces  
  • Flexible connectors should be installed in such a way that both ends can absorb both tension and compression 
  • For heights > 400 mm, extension pieces are required due to construction  
  • The fixing holes in the flexible connectors and extension pieces match those in the fire damper flanges 
  • Flexible connectors are also available separately
  • For further information relevant to design, in particular information on installation situations, please refer to the operating and installation manual. 

Materials and surfaces 
  • Flexible connectors made of fibre-reinforced plastic (fire behaviour according to DIN 4102; B2) and galvanised steel 
  • Extension pieces (height-dependent) made of galvanised sheet steel (and powder-coated silver grey, RAL 7001, when used with powder-coated (1) and stainless steel (2) dampers)

Operating side

Installation side

Order code

Casing length

Flexible connector S0

305/500

Flexible connector 0S

500

Flexible connector Flexible connector SS

500

Flexible connector Cover grille SA

500

Cover grille Flexible connector AS

500

Flexible connector Circular spigot SR

500

Circular spigot Flexible connector RS

500

Flexible connector Profile connecting frame SF

305/500

Profile connecting frame Flexible connector FS

500


Accessories 2 – Profile connecting frame

Application 

  • Profile connecting frames are required for the connection of ducts using a sluice gate valve 
  • In addition to the 4-screw corner joints, the duct and profile connecting frame are connected by means of a sluice gate valve. 

Note 
  • Lower leakage rates can be achieved when profile connecting frames are installed than when using a flange screw connection 
  • Profile connecting frames have a sliding rebate  
  • The fixing holes in the profile connecting frame match those in the fire damper flanges 
  • Profile connecting frames are also available separately 
  • For further information relevant to design, in particular information on installation situations, please refer to the operating and installation manual 

Materials and surfaces
  • Profile connecting frame made of galvanised steel 

Operating side

Installation side

Order code

Casing length

Profile connecting frame F0

305/500

Profile connecting frame 0F

305/500

Profile connecting frame Profile connecting frame FF

305/500

Profile connecting frame Flexible connector FS

500

Flexible connector Profile connecting frame SF

305/500

Profile connecting frame Cover grille FA

500

Cover grille Profile connecting frame AF

305/500

Profile connecting frame Circular spigot FR

500

Circular spigot Profile connecting frame RF

305/500


Accessories 2 – Circular spigot

Application

  • Circular spigots for rectangular FK2-EU fire dampers facilitate the direct connection of circular ducts.
Note 
  • Extension pieces are required for heights > 400 mm due to construction 
  • Circular spigots and, if applicable, extension pieces are factory assembled to form a unit 
  • The fixing holes in the round spigots match those in the fire damper flanges 
  • Round spigots are also available separately 
  • For further information relevant to design, in particular information on installation situations, please refer to the operating and installation manual. 

Materials and surfaces
  • Circular spigots made of galvanised sheet steel (and powdercoated silver grey, RAL 7001, when used with powder-coated (1) and stainless steel (2) dampers) 

Operating side

Installation side

Order code

Casing length

Circular spigot R0

305/500

Circular spigot 0R

500

Circular spigot Circular spigot RR

500

Circular spigot Flexible connector RS

500

Flexible connector Circular spigot SR

500

Circular spigot Cover grille RA

500

Cover grille Circular spigot AR

500

Circular spigot Profile connecting frame RF

305/500

Profile connecting frame Circular spigot FR

500


Dimensions [mm]

Nominal size

B×H

øD

200

200 × 200

198

250

250 × 250

248

300

300 × 300

248

350

350 × 350

313

400

400 × 400

398

450

450 × 450

448

500

500 × 500

498

550

550 × 550

498

600

600 × 600

558

650

650 × 650

628

700

700 × 700

628

750

750 × 750

708

800

800 × 800

798




Accessories 2 – Extension pieces


Application 
  • When there are cover grilles, circular spigots, flexible connectors, moulds, etc., you may have to use an extension piece for certain heights 

Note 
  • The movement of the damper blade must not be obstructed. 
  • The distance between the tip of the open damper blade and attachments (moulded parts, etc.) or any accessory should be at least 50 mm 
  • Fire dampers with flexible connectors, cover grilles and round spigots, including extension parts, are supplied (depending on height) 
  • The fixing holes in the extension pieces match those in the fire damper flanges
  • Extension pieces are also available separately 
  • For further information relevant to design, in particular information on installation situations, please refer to the operating and installation manual. 

Materials and surfaces
  • Extension pieces made of galvanised sheet steel, length 195 mm (and powder-coated silver grey (RAL 7001), when used with powder-coated (1) and stainless steel (2) dampers) 

Open blade protrusion [mm]

H

100

150

200

250

300

350

400

450

500

550

600

650

700

750

800

x

-204

-179

-154

-129

-104

-79

-54

-29 *

-4 *

21 *

46 *

71 *

96 *

121 *

146 *

y (1)

-8 *

17 *

42 *

67 *

92 *

117 *

142 *

167 **

192 **

217 **

242 **

267 **

292 **

317 **

342 **

y (2)

-204

-179

-154

-129

-104

-79

-54

-29 *

-4 *

21 *

46 *

71 *

96 *

121 *

146 *


* 1 Extension piece required
** 2 Extension pieces required
(1) L = 305 mm
(2) L = 500 mm

Arrangement of extension pieces

L

H

Operating side

Installation side

305

100 – 400

195

305

405 – 800

195

2 × 195

500

100 – 400

500

405 – 800

195

195


Attachment – Limit switch

FK2-EU (fusible link construction) with limit switch
Application 

  • Limit switches with volt-free contacts can indicate the damper blade position 
  • Up to the maximum switch rating, relays or indicator lights for fire alarm systems can be used 
  • One limit switch each is required for damper blade positions OPEN and CLOSED 
  • Fire dampers with a fusible link can be supplied or retrofitted with one or two limit switches (a conversion kit is required for a retrofit). 
  • For the technical data and wiring examples, see the installation and operating manual for FK2-EU.

Attachment

Order code

Limit switch for damper blade position CLOSEDZ01
Limit switch for damper blade position OPENZ02
Limit switches for damper blade positions CLOSED and OPENZ03



Attachment – Limit switch in explosion-proof construction

FK2-EU (fusible link construction) with limit switch in explosion-proof construction 
Application 

  • Explosion-proof limit switches with volt-free contacts can indicate the damper blade position 
  • Declaration of conformity: EPS 20 ATEX 2 058 X 
  • Up to the maximum switch rating, relays or indicator lights for fire alarm systems can be used 
  • The limit switches must be connected in a separately approved casing with a type of protection according to EN 60079-0 
  • One limit switch each is required for damper blade positions OPEN and CLOSED 
  • Fire dampers with a fusible link can be supplied or retrofitted with one or two limit switches (a conversion kit is required for a retrofit) 
  • Technical data and wiring examples, see additional operating manual "Explosion-protected fire dampers, type FK2-EU"

Attachment

Order code

Limit switch for damper blade position CLOSEDZ01EX
Limit switch for damper blade position OPENZ02EX
Limit switches for damper blade positions CLOSED and OPENZ03EX

Type of actuation

Release mechanism

Labelling

Ambient temperature

Maximum airflow velocity

Spring mechanismFusible linkII 2G Ex h IIC T6 Gb

II 2D Ex h IIIC T80°C Db
-40 – 40 °C8 m/s
Spring mechanismFusible link and limit switchII 2G Ex h IIC T6 Gb

II 2D Ex h IIIC T80°C Db
-20 – 40 °C8 m/s



Attachment – Spring return actuator

FK2-EU with spring return actuator 
Application 
  • A spring return actuator allows for the remote control of the fire damper and/or release by a suitable duct smoke detector 
  • If the supply voltage fails, or with thermoelectric release, the damper closes (power off to close) 
  • Motorised fire dampers can be used to shut off ducts 
  • Two integral limit switches with volt-free contacts can indicate the damper blade position (OPEN and CLOSED)
  • The connecting cables of the 24 V Belimo spring return actuator are fitted with plugs. This ensures quick and easy connection to the TROX AS-i bus system. Without automation components, the 24 V connection is made via a safety transformer provided by others 
  • A conversion kit is available for retrofitting an actuator to a fire damper with fusible link 
  • For the technical data and wiring examples, see the installation and operating manual for FK2-EU

Attachment

Order code

Spring return actuator 230 V (Belimo)Z43 
Spring return actuator 24 V (Belimo)Z45 
Spring return actuator 24 V (Belimo) including power supply unit BKN230-24-C-MP TRZ60 
Spring return actuator 24 V (Belimo) including power supply unit BKN230-24-C-MP TR and control module BKS24-1 TRZ61 
Spring return actuator 230 V (Siemens)Z43S
Spring return actuator 24 V (Siemens)Z45S


Attachment – Explosion-proof spring return actuator

FK2-EU with explosion-proof spring return actuator
Application 

  • A spring return actuator allows for the remote control of the fire damper and/or release by a suitable duct smoke detector 
  • The fire damper can be used in supply and extract air systems in areas with potentially explosive atmospheres 
  • If the supply voltage fails, or with thermoelectric release, the damper closes (power off to close) 
  • Fire dampers with spring return actuators can be functionally checked OPEN/CLOSED/OPEN 
  • Two integral limit switches with volt-free contacts can indicate the damper blade position (OPEN and CLOSED) 
  • The electrical connection is made in the explosion-proof terminal box 
  • Release temperature of the spring return actuator 72°C 
  • Declaration of conformity: EPS 20 ATEX 2 058 X 
  • Technical data and wiring examples, see additional operating manual "Explosion-protected fire dampers, type FK2-EU" 

Use in areas with potentially explosive atmospheres (ATEX)
  • According to declaration of conformity EPS 20 ATEX 2 058 X, the fire damper may be used in the following areas with potentially explosive atmospheres. The ambient temperatures and types of release and actuation specified in the technical data are binding. 

ExMax
  • Zones 1, 2: Gases, mists and vapours Zones 21, 22: Dusts 

RedMax
  • Zone 2: Gases, mists and vapours Zone 22: Dusts

Attachment

Order code

ExMax-15-BF TRZEX1
RedMax-15-BF TRZEX3

Type of actuation

Release mechanism

Labelling

Ambient temperature

Maximum airflow velocity

ExMax-15-BF TRExPro-TT *II 2G Ex h IIC T6 Gb

II 2D Ex h IIIC T80°C Db
-40 – 40 °C10 m/s
RedMax-15-BF TRExPro-TT *II 3G Ex h IIC T6 Gc

II 3D Ex h IIIC T80°C Dc
-40 – 40 °C10 m/s

* Release temperature: 72 °C



Attachment – Spring return actuator and RM-O-3-D

FK2-EU with spring return actuator and duct smoke detector RM-O-3-D
Application 

  • An open/close actuator allows for remote control of the fire damper and/or release by a suitable duct smoke detector 
  • If the supply voltage fails, or with thermoelectric release or smoke detection the damper closes (power off to close) 
  • Motorised fire dampers can be used to shut off ducts 
  • Two integral limit switches with volt-free contacts can indicate the damper blade position (OPEN and CLOSED) 
  • The type RM-O-3-D duct smoke detector must be installed in the lower inspection access and arranged at the top when assembling the fire damper 
  • For the technical data and wiring examples, see the installation and operating manual for FK2-EU and/or the operating and installation manual for duct smoke detector type RM-O-3-D

Attachment

Order code

With spring return actuator 230 V (Belimo) and integrated duct smoke detector type RM-O-3-D

Z43RM1

With spring return actuator 24 V (Belimo) and integrated duct smoke detector type RM-O-3-D

Z45RM1

With spring return actuator 230 V (Siemens) and integrated duct smoke detector type RM-O-3-D

Z43RMS1

With spring return actuator 24 V (Siemens) and integrated duct smoke detector type RM-O-3-D

Z45RMS1

1: If the unit is not connected to ducting, cover grilles are required on both ends. When combined with a spring return actuator, a duct smoke detector RM-O-3-D and cover grilles on both ends, this is an air transfer damper with general building inspectorate licence: Z-6.50-2540.

The duct smoke detector can be installed on the operation and installation side.


Attachment – Spring return actuator and TROXNETCOM

FK2-EU with spring return actuator and TROXNETCOM 
Application

  • Fire dampers with a 24 V spring return actuator (Belimo) and the modules described here as attachments form a functional unit ready for automatic operation 
  • The components are factory mounted and wired 
  • The combination spring return actuator with TROXNETCOM enables brand-neutral and cross-sector integration of various components (modules) in one network 
  • The modules control actuators and/or receive signals from sensors 

AS-i
  • AS interface is a global standard bus system according to EN 50295 and IEC 62026-2 
  • The module transmits the control signals between the spring return actuator and the controller and power unit
  • The control of the actuator and monitoring of run time for functional tests is thus possible 
  • The voltage (24 V DC) for the module and the actuator is supplied via the two-wire AS-i flat cable 
  • Function display: operation, 4 inputs, 2 outputs 

MODBUS RTU/BACnet MS/TP (RS485) 
  • MODBUS RTU and BACnet MS/TP are protocols for RS485 communication systems 
  • Data transmission is based on uniform protocols 
  • Only the bus line and the supply voltage remain to be connected by others 
  • MB-BAC-WA1/2: for the control of 1 – 2 fire dampers 
  • WA1/B3-AD: junction box for the 2nd fire damper with 24 V DC supply voltage to the MB-BAC-WA1/2 
  • WA1/B3-AD230: junction box with integrated power supply unit 230/24 V for connection of a 2nd motor-driven 24 V fire damper to the MB-BAC-WA1/2 LON 

LON 
  • LON indicates a standard local operating network system with manufacturer-independent communications 
  • Data transmission is based on a uniform protocol 
  • LonMark defines standards to ensure product compatibility 
  • Only the bus line and the supply voltage remain to be connected by others 
  • LON-WA1/B3: for the control of 1 – 2 fire dampers 
  • WA1/B3-AD: junction box for the 2nd fire damper with 24 V DC supply voltage to the LON-WA1/B3 
  • WA1/B3-AD230: Connection box with integral 230/24 V power supply unit for the connection of a second actuator-driven 24 V fire damper to LON‑A1/B3 

TNC‑EASYCONTROL
  • TNC-EASYCONTROL TNC-LINKBOX is a wiring aid for connecting a fire damper and the configurable parallel circuit for the TNCEASYCONTROL decentralised operating and monitoring system.

Attachment

Order code

Spring return actuator 24 V and AS-EMZA07
Spring return actuator 24 V, RM-O-3-D and AS-EMZA12
Spring return actuator 24 V and MB-BAC-WA1/2ZB01
Spring return actuator 24 V and LON-WA1/B3ZL09
Spring return actuator 24 V and WA1/B3-ADZL10
Spring return actuator 24 V and WA1/B3-AD230ZL11
Spring return actuator 24 V and TNC-LinkboxZA14
Spring return actuator 24 V and MB-BAC-WA1/2ZB01


Attachment – Explosion-proof spring return actuator and TROXNETCOM

FK2-EU with explosion-proof spring return actuator and TROXNETCOM 
Application 

  • The fire dampers with spring return actuator ExMax/ RedMax-15-BF-TR and module AS-EM/C form a functional unit ready for automatic operation 
  • The combination explosion-protected spring return actuator with TROXNETCOM enables brand-neutral and cross-sector integration of various components (modules) in one network 
  • The modules control actuators and/or receive signals from sensors The module is to be installed and wired outside the potentially explosive atmosphere by others 

AS-i
  • AS interface is a global standard bus system according to EN 50295 and IEC 62026-2 
  • The module transmits the control signals between the spring return actuator and the controller and power unit 
  • The control of the actuator and monitoring of run time for functional tests is thus possible 
  • Function display: operation, 4 inputs, 2 outputs

AttachmentOrder code

ExMax-15-BF TR and AS-EM/C

ZEX2

RedMax-15-BF TR and AS-EM/C

ZEX4



Attachment – Duct smoke detectors

Application

  • To prevent smoke from spreading in buildings, it is extremely important that the smoke is detected at an early stage 
  • Duct smoke detectors that operate on the principle of light scattering detect the smoke regardless of its temperature so that the fire dampers can be closed before the release temperature of 72°C is reached 
  • If the air contains suspended particles, as is the case with smoke, beams of light are deflected off these. A sensor (photodiode), which does not receive light in clear air, is illuminated by the scattered light 
  • The fire damper or smoke protection damper blade is released when the brightness of the scattered light exceeds a certain threshold 

Attachment

Order code

Duct smoke detector

RM-O-3-D

Duct smoke detector

RM-O-VS-D


Duct smoke detectors are attachments and to be ordered separately.
RM-O-3-D can also be supplied assembled and wired for FK2-EU with standard application.

CONVERSION FROM FUSIBLE LINK TO SPRING RETURN ACTUATOR

CONVERSION FROM SPRING RETURN ACTUATOR TO FUSIBLE LINK

MOUNTING LIMIT SWITCH

DOWNLOADS

product information

brochures

certificates

operation manuals

production {"X-Frame-Options"=>"SAMEORIGIN", "X-XSS-Protection"=>"1; mode=block", "X-Content-Type-Options"=>"nosniff", "X-Download-Options"=>"noopen", "X-Permitted-Cross-Domain-Policies"=>"none", "Referrer-Policy"=>"strict-origin-when-cross-origin", "Content-Security-Policy"=>"frame-ancestors 'self' https://*.scrivito.com https://punchoutcommerce.com https://www.trox.de https://trox-extern.com https://*.onventis.com http://localhost:63342 http://cerebrum.local", "Strict-Transport-Security"=>"max-age=31536000; includeSubDomains", "Content-Type"=>"text/html; charset=utf-8"}

Share page

Recommend this page

Recommend this page by sending a link by mail.

Fields marked with an (*) are required fields.

Share page

Thank you for your recommendation!

Your recommendation has been sent and should arrive shortly.

Contact

We are here for you

Please specify your message and type of request
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265

Contact

We are here for you

Please specify your message and type of request
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265

Attachment (max. 10MB)

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265