Application
Special features
Nominal sizes
Variants
Construction
Parts and characteristics
Attachments
Accessories
Materials and surfaces
Galvanised sheet steel construction
Powder-coated construction (P1)
Stainless steel construction (A2)
Standards and guidelines
Maintenance
Maintenance-free, as construction and materials are not subject to wear and tear
Functional description
For airtight shut-off of volume flows in round air ducts. The basic version is shut off by manually actuating the damper blade. Electrically or pneumatically operated actuators, which are available in different versions, can also be used to operate the damper blade. The versions differ with regard to the power supply and safety position (de-energised or de-pressurised state). Actuators with auxiliary switches for electrical monitoring of the damper blade position are also available.
The actuator of a damper blade must be controlled by a customer-side circuit and then moves the damper blade to the OPEN or CLOSED position.
Nominal sizes | 100 – 400 mm |
Acceptable static differential pressure | 1500 Pa |
Operating temperature | 10 – 50 °C |
This specification text describes the general properties of the product. Texts for variants can be generated with our Easy Product Finder design programme
Circular shut-off dampers for shutting off or restricting the airflow in ventilation ducts of air conditioning systems, for supply air or extract air, available in 7 nominal sizes Suitable for duct pressures up to 1500 Pa.
Ready-to-install unit consists of the casing with a damper blade.
Spigot with groove for lip seal, suitable for connecting ducts according to EN 1506 or EN 13180. Position of the damper blade indicated externally at the shaft extension.
Closed blade air leakage to EN 1751, class 4 (nominal sizes 100, 125 and 160, class 3).
Casing air leakage to EN 1751, class C.
Special features
Materials and surfaces
Galvanised sheet steel construction
Powder-coated construction (P1)
Stainless steel construction (A2)
Construction
Technical data
Sizing data
Air-regenerated noise
This specification text describes the general properties of the product. Texts for variants can be generated with our Easy Product Finder design programme.
AK | – | P1 | – | FL | / | 160 | / | G2 | / | BP0 | / | NO |
| | | | | | | | | | | | | | ||||||
1 | 2 | 3 | 4 | 5 | 6 | 7 |
Open/Close actuators
B30 24 V AC/DC, 3-point
B32 24 V AC/DC, 3-point, with auxiliary switch
B40 230 V AC, 3-point
B42 230 V AC, 3-point, with auxiliary switch
Open/Close actuators
BP0 24 V AC/DC, spring return
BP2 24 V AC/DC, spring return, with auxiliary switch
BR0 24 - 240 V AC, 24 - 125 V DC, spring return, with safe position
BR2 24 - 240 V AC, 24 - 125 V DC, spring return, with auxiliary switch, with safe position
Modulating actuators
B20 24 V AC/DC, modulating, 2 – 10 V DC
B22 24 V AC/DC, continuous 2 - 10 V DC, with auxiliary switch
Pneumatic actuator with safe position
TN0 Pneumatic actuator 0.2 – 1 bar
Share page
Recommend this page
Recommend this page by sending a link by mail.
Share page
Thank you for your recommendation!
Your recommendation has been sent and should arrive shortly.
Contact
We are here for you
Please specify your message and type of request
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265
Contact
Thank you for your message!
Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265
Contact
We are here for you
Please specify your message and type of request
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265
Contact
Thank you for your message!
Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265