small_tab1_Serie SIF
market_image_1
market_image_2
small_tab1_Serie SIF
market_image_1
market_image_2
Configure now

Type SIF

Fitting of filter elements for the separation of coarse and fine dust

 

Standard cell frame for pocket filters, Mini Pleat filter inserts, activated carbon filter inserts, Mini Pleat filter panels with plastic frames, filters, and cut-to-size filter pads. For installation into ventilation systems

  • Highly variable since parts of various sizes can be combined
  • Robust construction
  • Perfect compensation of tolerances due to perimeter groove in standard cell frame
  • Cell frames with a groove provide various tensioning options depending on the filter frame depth
  • Easy handling and secure sealing due to four special clamping elements and a foamed, closed-cell, silicone-free continuous seal
  • Meets the hygiene requirements of VDI 6022


Optional equipment and accessories

  • Stainless steel construction
v2.5.1.2
Updating order code
Save configuration
Calculate price
Variant
B
E
Tensioning depth
25
Material
GAL
STA
Cellframes (horizontal)
Cellframes (vertical)
Updating technical data
Specification text: SIF-B-25-GAL/2x3
Updating specification text

Filter wall type SIF for installation into ventilation systems. Fitting of filter elements for the separation of coarse dust and fine dust and for the adsorption of gaseous odorous substances and contaminants.
Filter wall consisting of standard cell frames with perimeter groove as base element, installation subframes, and flat steel stiffeners.
Four clamping elements for secure sealing between the cell frame and the filter element.
The installation subframe is inserted into the groove of the cell frame and bolted into place at the corners. The flat steel stiffeners provide static stability. The filter wall meets the hygiene requirements of VDI 6022.

VARIANT
B Variant: Frame with perimeter groove
25 Tensioning depth: 25
GAL Material: Galvanised steel
2 Cellframes (horizontal): 2
3 Cellframes (vertical): 3

PRODUCT DATA
Filter element type Pocket filters
Width B 1.225 mm
Height H 1.830 mm
Depth T 80 mm
592 × 592 n1×1 6
287 × 592 n½×1 0
592 × 287 n1×½ 0
Nominal volume flow rate qv,nom 20.400 m³/h
Filter element nominal volume flow rate qv,nom,1×1 3.400 m³/h

Manufacturer: TROX GmbH
Type: SIF-B-25-GAL/2x3

Show complete text Hide complete text

Application

Application

  • Filter wall type SIF for ventilation systems
  • Fitting of filter elements for the separation of coarse and fine dust
  • Fitting of filter elements for the adsorption of gaseous odorous substances and contaminants
  • Filter wall for pocket filters, Mini Pleat filter inserts, activated carbon filter inserts, Mini Pleat filter panels with plastic frames

Description

Variants

  • B: Frame with perimeter groove
  • Tensioning depth: 25 mm

Construction

  • GAL: Galvanised steel
  • STA: Stainless steel

Useful additions

  • Suitable filter elements to be ordered separately
  • Pocket filters made of non-woven chemical fibres (PFC)
  • Pocket filters made of non-woven synthetic fibres (PFS)
  • Pocket filters made of NanoWave® medium (PFN)
  • Pocket filters made of non-woven glass fibres (PFG)
  • Mini Pleat filter inserts (MFI)
  • Activated carbon filter inserts (ACFI)
  • Mini Pleat filter panels (MFP, construction PLA)

Construction features

  • Four clamping elements for secure sealing between the cell frame and the filter elements
  • Cell frame with perimeter groove

Materials and surfaces

  • Standard cell frames, installation subframes, and flat steel stiffeners made of galvanised sheet steel or stainless steel

Technical information

  • Function
  • Specification text
  • Order code

 

Filter wall type SIF for installation into ventilation systems. Fitting of filter elements for the separation of coarse dust and fine dust and for the adsorption of gaseous odorous substances and contaminants.

Filter wall consisting of standard cell frames with perimeter groove as base element, installation subframes, and flat steel stiffeners.

Standard cell frame with perimeter groove for various filter frame depths.

Four spring clips for secure sealing between the cell frame and the filter element.

The installation subframe is inserted into the groove of the cell frame and bolted into place at the corners. The flat steel stiffeners provide static stability. The filter wall meets the hygiene requirements of VDI 6022.

Materials and surfaces

  • Standard cell frames, installation subframes, and flat steel stiffeners made of galvanised sheet steel or stainless steel

Construction

  • GAL: Galvanised steel
  • STA: Stainless steel
sif

Downloads

product information

certificates

Share page

Recommend this page

Recommend this page by sending a link by mail.

Fields marked with an (*) are required fields.

Share page

Thank you for your recommendation!

Your recommendation has been sent and should arrive shortly.

Contact

We are here for you

Visual contact Visual contact

Please specify your message and type of request
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Visual contact Visual contact

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265

Contact

We are here for you

Visual contact Visual contact

Please specify your message and type of request
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265

Attachment (max. 10MB)

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Visual contact Visual contact

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265