Type EM-AUTOZERO

Automatic zero point correction for EASYLAB

Expansion module for EASYLAB controllers that offers automatic zero point correction for long-term stable volume flow rate measurement and reduced maintenance

  • Particularly recommended for the volume flow or differential pressure measurement in sensitive areas
  • EASYLAB controller automatically identifies and uses the expansion module
  • The expansion module is fitted into the casing with the EASYLAB base component
  • Easy retrofitting
  • No additional configuration effort

Expansion module EM-AUTOZERO 00135585_0
  • Application
  • Description

Application

  • Expansion module Type EM-AUTOZERO for the EASYLAB system
  • EM-AUTOZERO, automatic zero point correction for long-term stable volume flow rate measurement and reduced maintenance.
  • Can be used with fume cupboard, supply air, extract air or differential pressure controller EASYLAB TCU3
  • For use in laboratories, clean rooms in the pharmaceutical and semiconductor industries, operating theatres, intensive care units, and offices with very demanding control requirements

Special characteristics

  • Long-term stable volume flow rate measurement and reduced maintenance
  • Automatic zero point correction as soon as the supply voltage is applied
  • Cyclical zero point correction during operation (every 8 hours)
  • No additional configuration effort
  • The EASYLAB controller identifies the expansion module automatically

Parts and characteristics

  • Solenoid valve
  • 2-pole plug-in connection cable for the connection to the EASYLAB main PCB
  • Tubes for the connection of the static differential pressure transducer

Construction features

  • Dimensions and fixing correspond to the EASYLAB casing
  • The expansion module is inserted into a recess of the holder for the differential pressure transducer (no tools required)
  • Integration with the tube connection between the static differential pressure transducer and the differential pressure sensor
  • Plug ensures easy connection to the EASYLAB controller

Technical information

  • Function
  • Technical data
  • Specification text
  • Order code
EM-AUTOZERO 00133875_0

① Magnetventil

② Plugg

③ Differansetrykksensor – plusstilkobling

④ Differansetrykksensor – minustilkobling

⑤ Trykkgiver – minustilkobling

⑥Trykkgiver – plusstilkobling

The solenoid valve of the EM-AUTOZERO expansion module is integrated with the tube connection between the static differential pressure transducer and the differential pressure sensor of the VAV terminal unit.

The TCU3 controller provides the control input signal for cyclical zero point corrections.

For this purpose, the measuring tubes of the differential pressure transducer are temporarily short circuited, then the zero voltage is measured.

This measured value is used as a correction value for the volume flow rate measurement until the next zero point correction.

Supply voltage24 V DC from the controller TCU3
Power rating1.8 W
Maximum pressure10 bar
Operating temperature0 – 50 °C
IEC protection classIII (protective extra-low voltage)
Protection levelIP 20
EC conformityEMC according to 2004/108/EC
Weight0.100 kg


Expansion module for the EASYLAB controller TCU3, used for automatic zero point correction.

Long-term stable volume flow rate measurement and reduced maintenance.

The expansion module comprises a solenoid valve, the connection cable and connection tubes.

Special characteristics

  • Long-term stable volume flow rate measurement and reduced maintenance
  • Automatic zero point correction as soon as the supply voltage is applied
  • Cyclical zero point correction during operation (every 8 hours)
  • No additional configuration effort
  • The EASYLAB controller identifies the expansion module automatically

Technical data

  • Solenoid valve
  • Supply voltage 24 V DC from the controller TCU3
  • Power rating 1.8 W
  • Maximum pressure 10 bar
  • Protection level IP 20

em-autozero

Share page

Recommend this page

Recommend this page by sending a link by mail.

Fields marked with an (*) are required fields.

Share page

Thank you for your recommendation!

Your recommendation has been sent and should arrive shortly.


Contact

We are here for you

Visual contact Visual contact

Please specify your message and type of request
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Visual contact Visual contact

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265

Contact

We are here for you

Visual contact Visual contact

Please specify your message and type of request
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265

Attachment (max. 10MB)

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Visual contact Visual contact

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265